BA24
42
UK
AUTOMATIC CLOSING
PAUSE TIME
H9
Determines the pause time in opening before automatic closing.
Tmax 300 sec.
PEDESTRIAN OPENING TIME
H10
Determines the pedestrian opening time.Tmax 300 sec.
AUTOMATIC PEDESTRIAN
CLOSING PAUSE TIME
H11
Determines the pause time in pedestrian opening bifore automatic closing.
Tmax 300 sec.
CYCLES NUMBER
H12
Allows the setting of a number of cycles ( closing) before the
maintenance request.
The value set will always be multiplied for 10.
If 0000 is set, the numbering is excluded.
When the set number of cycles is reached, the maintenance request is signalled
by a slow blink of 60 sec. at the end of the movement.
WARNING: every time you enter the menu H12 the cycles numbering is reset
and starts again.
INSTALLER CODE
H13
Allows the input of the installer code to customize the settings during the
programming phase.
The INSTALLER CODE is the only way to enter the programming menu.
WARNING:
in case of loss of the installer code, it will be possible to delete the
old one by pressing simultaneously the keys + and – for 3 seconds when the
writing PASS appears.
In this way, all the existing setting are erased and the default ones are
automatically set. Only the settings of the performed cycles are still stored in
memory.
SOFTWARE VERSION
H14
Shows the firmware version installed on the equipment. (R__XX)
LEAF 2 PHASE SHIFT TIME
IN OPENING
H7
Delay the start in opening of leaf 2 with respect to leaf 1.
In the case of double sliding gate, the time H7 will not be considered.
Tmax 100 sec.
LEAF 1 PHASE SHIFT TIME
IN CLOSING
H8
Delay the start in opening of leaf 1 with respect to leaf 2. In the case of double
sliding gate, the time H8 will not be considered. Tmax 100 sec.
NUMBER OF PERFORMED CYCLES
H15
Number of performed cycles.
The value displayed on the LCD is increased every 10 movements.
MENU E: EXTERNAL DEVICES ENABLING-DISABLING
KEY +:
enters the following menu E1-E2-E3...
KEY - :
accede al menu precedente E3-E2-E1…
KEY ESC:
leaves the menu
KEY OK:
enables (Y) / disables (N) the function
WARNING: The STOP key cannot be excluded in menu E. If it is not used, jumper the clamps 20-29.
Содержание Gi.Bi.Di. BA24
Страница 173: ...IP55 2 10A 3 mm 2 5 mm 0 5 mm N C N A 2 1 2 3 BA24 173 GR...
Страница 190: ...START 1 2 START 2 1 START 1 C21 Y OK C6 H3 H6 ESC Gbd H3 H6 T3 T3 T3 AP CH BA24 190 GR...
Страница 191: ...24V 24V 20 21 Vdc 4 s 16V 4 s 3 PASS 5 2 start 3 start 3 start 4 1 4 1 4 4 3 N C 3 N C 2 8K2 BA24 191 GR...
Страница 196: ...NOTE BA24 196...
Страница 197: ...NOTE BA24 197...
Страница 198: ...NOTE BA24 198...