118
BVS HS-Q Series
Standard Hand Held Barcode Reader
Enter/Exit Programming Mode
4
Configuration Using Barcodes
Code 128
The following options apply to the Code 128 symbology.
Code 128 Enable/Disable
When disabled, the reader will not read Code 128 barcodes.
Expand Code 128 to Code 39
This feature enables/disables expansion of Code 128 labels to Code 39 labels.
Code 128 Check Character Transmission
Enable this option to transmit the check character along with Code 128 barcode data.
Code 128 = Disable
Code 128 = Enable
Code 128 to Code 39 = Don’t Expand
Code 128 to Code 39 = Expand
Code 128 Check Character Transmission =
Don’t Send
Code 128 Check Character Transmission =
Send
C8EN00(CR
CC8EN01(CR
DEFAULT
DEFAULT
C8C300(CR
CC8C301(CR
DEFAULT
C8CT00(CR
CC8CT01(CR