79
www.balluff.com
BVS HS-Q Series
Standard Hand Held Barcode Reader
Enter/Exit Programming Mode
4
Configuration Using Barcodes
Stand Mode Illumination Off Time
Specifies the amount of time reader illumination stays off after pulling the trigger when in Stand
Mode. The configurable range is 01 to 32 by 01 in increments of 500ms (500ms to 16 seconds).
See
in “References” for a description of this feature.
Reading Active Time
This setting specifies the amount of time that the reader stays in scan ON state once the state is
entered. The range for this setting is from 1 to 255 seconds in 1-second increments. See
in “References” for further description of this feature.
Select Stand Mode Time Setting
To configure this feature, scan the ENTER/
EXIT PROGRAMMING MODE barcode
above, then the barcode at left followed by
the digits from the Alphanumeric characters
in
Appendix 18, Use the barcodes in this
appendix to enter numbers as you would
select digits/characters from a keypad.
rep-
resenting your desired character(s). End by
reading the ENTER/EXIT barcode again.
Reading Active Time = 3 seconds
Reading Active Time = 5 seconds
Reading Active Time = 8 seconds
$CSNTM
DEFAULT
04 = 2 Seconds
CSNET03(CR
CSNET05(CR
DEFAULT
CSNET08(CR