190
BVS HS-Q Series
Standard Hand Held Barcode Reader
Enter/Exit Programming Mode
4
Configuration Using Barcodes
Maxicode
Length Control
This feature specifies either variable length decoding or fixed length decoding for this symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
Maxicode Set Length 1
Specifies one of the barcode lengths for
Maxicode Length Control on page 190
. Length 1 is the
minimum label length if in
Variable Length
Mode, or the first fixed length if in Fixed Length Mode.
Characters can be set from 0001 to 0145 characters in increments of 0001 (pad with zeroes).
See
for detailed instructions on setting this feature.
Maxicode Length Control = Variable Length
Maxicode Length Control = Fixed Length
Select Maxicode Length 1 Setting
To configure this feature, scan the ENTER/
EXIT PROGRAMMING MODE barcode
above, then the barcode at left followed by
the digits from the Alphanumeric characters
in
Appendix 18, Use the barcodes in this
appendix to enter numbers as you would
select digits/characters from a keypad.
rep-
resenting your desired character(s). End by
reading the ENTER/EXIT barcode again.
Make a mistake? Scan the CANCEL barcode
to abort and not save the entry string. You
can then start again at the beginning.
CANCEL
DEFAULT
$CMX-
$CMX-
$CMXL1
~
DEFAULT
0001 = Length 1 is 1 Character