![Balluff BTL7-T500 Series Скачать руководство пользователя страница 66](http://html.mh-extra.com/html/balluff/btl7-t500-series/btl7-t500-series_configuration-manual_469551066.webp)
www.balluff.com
25
english
4
Configuration (continued)
Error number
Meaning
16#00
Non-permissible parameter (parameter not available)
16#01
Parameter value cannot be changed
16#02
Upper or lower limit exceeded (parameter outside the permitted range)
16#03
Incorrect subindex (subindex not present)
16#04
No array (access with subindex to element without subindices)
16#05
Wrong data type
16#07
Element cannot be changed (write access to a read-only element)
16#09
No description data available (parameter is available but not description data)
16#0B
No write permission (access to a parameter without the necessary permissions)
16#11
Access not possible because of current operating state (reason not specified)
16#15
Response too long (response would exceed the maximum permissible length)
16#16
Non-permissible parameter address (attribute, number of elements, parameter number or subindex is
not supported)
16#17
Invalid format (write access with wrong format)
16#18
Number of values not consistent (write access)
16#65
Save error (saving the data in non-volatile memory failed)
Tab. 4-14: Error codes DPV1