www.baldormotion.com
5-36 Operation
MN1941
5.9.2 Adjusting KPROP
The KPROP term can be used to reduce following error. Its value will usually be much smaller
than the value used for an equivalent current controlled system. A fractional value, for example
0.1, will probably be a good starting figure which can then be increased slowly.
1. Click in the KPROP box and enter a starting
value of 0.1.
2. Click
Go
.
The NextMove
e
100 will perform the move and the motor will turn. As the soon as the move
is completed, Mint WorkBench will upload captured data from the NextMove
e
100. The data
will then be displayed in the Capture window as a graph.
Note:
The graph that you see will not look exactly the same as the graph shown here!
Remember that each motor has a different response.
3. Using the check boxes below the graph,
select the Measured position and Demand
position traces.
Содержание NXE100-1608Dx
Страница 1: ......
Страница 2: ......
Страница 16: ...www baldormotion com 3 4 Basic Installation MN1941 ...
Страница 50: ...www baldormotion com 4 34 Input Output MN1941 ...
Страница 77: ...www baldormotion com Operation 5 27 MN1941 Figure 37 The NextMove e100 servo loop ...
Страница 98: ...www baldormotion com 6 8 Troubleshooting MN1941 ...
Страница 110: ...Index MN1941 ...
Страница 112: ...Comments MN1941 Thank you for taking the time to help us ...
Страница 113: ......
Страница 114: ......