5.9 Local servo axis - tuning for velocity control
Drive amplifiers designed for velocity control incorporate their own velocity feedback term to
provide system damping. For this reason, KDERIV (and KVEL) can often be set to zero.
Correct setting of the velocity feed forward gain KVELFF is important to get the optimum
response from the system. The velocity feed forward term takes the instantaneous velocity
demand from the profile generator and adds this to the output block (see Figure 37).
KVELFF is outside the closed loop and therefore does not have an effect on system stability.
This means that the term can be increased to maximum without causing the motor to oscillate,
provided that other terms are setup correctly.
When setup correctly, KVELFF will cause the motor to move at the speed demanded by the
profile generator. This is true without the other terms in the closed loop doing anything except
compensating for small errors in the position of the motor. This gives faster response to changes
in demand speed, with reduced following error.
Before proceeding, confirm that the encoder feedback signals from the motor or drive amplifier
have been connected, and that a positive demand causes a positive feedback signal.
5.9.1 Calculating KVELFF
To calculate the correct value for KVELFF, you will need to know:
H
The speed, in revolutions per minute, produced by the motor when a maximum demand
(+10 V) is applied to the drive amplifier.
H
The axis’ position loop update rate (the Control Rate setting selected in the Config Local Axis
dialog - see section 5.5.3).
H
The resolution of the encoder input.
The servo loop formula uses speed values expressed in
quadrature counts per servo loop
. To
calculate this figure:
1. First, divide the speed of the motor, in revolutions per minute, by 60 to give the number of
revolutions per second. For example, if the motor speed is 3000 rpm when a maximum
demand (+10 V) is applied to the drive amplifier:
Revolutions per second
=
3000 / 60
=
50
2. Next, calculate how many revolutions will occur during one servo loop. The factory preset
position loop update rate is 1 kHz (0.001 seconds), so:
Revolutions per servo loop
=
50 x 0.001 seconds
=
0.05
3. Now calculate how many quadrature encoder counts there are per revolution. The
NextMove
e
100 counts both edges of both pulse trains (CHA and CHB) coming from the
encoder, so for every encoder line there are 4 ‘quadrature counts’. With a 1000 line encoder:
Quadrature counts per revolution
=
1000 x 4
=
4000
4. Finally, calculate how many quadrature counts there are per servo loop:
Quadrature counts per servo loop
=
4000 x 0.05
=
200
Содержание NXE100-1608Dx
Страница 1: ......
Страница 2: ......
Страница 16: ...www baldormotion com 3 4 Basic Installation MN1941 ...
Страница 50: ...www baldormotion com 4 34 Input Output MN1941 ...
Страница 77: ...www baldormotion com Operation 5 27 MN1941 Figure 37 The NextMove e100 servo loop ...
Страница 98: ...www baldormotion com 6 8 Troubleshooting MN1941 ...
Страница 110: ...Index MN1941 ...
Страница 112: ...Comments MN1941 Thank you for taking the time to help us ...
Страница 113: ......
Страница 114: ......