www.baldormotion.com
Operation 5-21
MN1941
5.5.6 Testing the drive enable output
1. On the main Mint WorkBench toolbar, click
the Axes button. In the Select Default Axes
dialog, select the axes to be controlled. Click
OK
to close the dialog.
2. On the main Mint WorkBench toolbar, click
the Drive enable button. Click the button
again. Each time you click the button, the
drive enable output(s) for the selected axes
are toggled.
When the button is in the pressed (down)
position the drive amplifier should be
enabled. When the button is in the raised (up)
position the drive amplifier should be
disabled.
If this is not working, or the action of the button is reversed, check the electrical connections
between the NextMove
e
100 and drive amplifier. If you are using the relay, check that you
are using the correct normally open (REL NO) or normally closed (REL NC) connections. If
you are using a digital output, check that it is using the correct high or low triggering method
expected by the drive amplifier.