3.9.7 Duty cycle
The regeneration duty cycle is the amount of time taken regenerating as a proportion of the overall
application cycle time. For example, Figure 25 shows a system which performs a trapezoidal
move profile, with regeneration during part of the deceleration phase. The regeneration duty is 0.2
(0.5 second regeneration / 2.5 second cycle time):
2.5 s
(Cycle time)
0.5 s
0.5 s
Regeneration active
t
v
0.5 s
Decel time
2.5 s
(Cycle time)
2.5 s
(Cycle time)
Figure 25 - Duty cycle = 0.2