www.baldormotion.com
3-28 Basic Installation
MN1943
3.7 Motor connections
Location
Connector X17 (bottom panel)
Mating connector
1.5 A ~ 16 A models
21 A ~ 33 A models
48 A ~ 65 A models
Phoenix POWER COMBICON PC 4/ 3-ST-7,62
Phoenix POWER COMBICON IPC 16/ 3-ST-10,16
Phoenix POWER COMBICON ISPC 16/ 3-ST-10,16
AC supply voltage
230 VAC, 3
Φ
480 VAC, 3
Φ
Output voltage range
0-230 VAC, 3
Φ
0-480 VAC, 3
Φ
MotiFlex
e
100 will operate with a large number of brushless servo motors. For information on
selecting Baldor servo motors please see the sales brochure BR1202, available from your local
Baldor representative. The motor must be capable of being powered by an inverter PWM output
- see sections 8.3.1 to 8.3.3 for details. The motor can be connected directly to the MotiFlex
e
100
or through a motor contactor (M-Contactor). The motor outputs are fully short-circuit proof
according to EN61800-5-1, 6.2. Motors should ideally have a minimum inductance of 1 mH per
winding; for motors with lower inductance an output reactor may be fitted in series with the motor.
When using a Baldor motor, the parameters for managing motor overloads are configured
automatically by the Commissioning Wizard (see section 6.4.3). If they need to be changed, or
you are using an alternative motor, use the Parameters tool in Mint WorkBench (see section
6.5.1).
For full motor output specifications, see section 8.3.
Hazardous voltages can exist on the motor output connections. Do not
touch the motor output connections before you first ensure there is no high
voltage present.
The motor leads U, V and W must be connected to their corresponding U, V or W
terminal on the motor. Misconnection will result in uncontrolled motor movement.
Do not connect AC supply power to the MotiFlex
e
100 UVW outputs. This could
damage the MotiFlex
e
100.
For CE compliance, the motor earth/ground should be connected to the drive earth/ground, and
the motor power cable must be shielded; see section 3.7.1. The connector or gland used at the
motor must provide 360 degree shielding. The maximum recommended cable length is 30.5 m
(100 ft). See section 3.4.12 for recommended wire sizes.
DANGER
NOTICE
NOTICE
Содержание MotiFlex e100
Страница 1: ......
Страница 2: ......
Страница 60: ...www baldormotion com 3 44 Basic Installation MN1943 ...
Страница 102: ...www baldormotion com 5 28 Input Output MN1943 ...
Страница 136: ...www baldormotion com 7 8 Troubleshooting MN1943 ...
Страница 172: ...www baldormotion com 8 36 Specifications MN1943 ...
Страница 188: ...www baldormotion com B 6 Control System MN1943 ...
Страница 204: ...www baldormotion com C 16 Mint Keyword Summary MN1943 ...
Страница 216: ...Index MN1943 ...
Страница 218: ...www baldormotion com Comments MN1943 Thank you for taking the time to help us ...
Страница 219: ......
Страница 220: ......