www.baldormotion.com
Basic Installation 3-19
MN1901
3.5.6 Motor brake connection
You might wish to wire a motor’s brake, via relays, to digital outputs on connector X3 (see
section 4.3.1). This provides a way for the Mint program to control the motor’s brake. A typical
circuit is shown in Figure 10.
C
D
from motor brake
connections
Separate
customer
supplied
24VDC supply
X3
8
18
19
DOUT0 (
OUTX.0
)
DOUT1 (
OUTX.1
)
CGND
Relay 2
Relay 1
+24VDC
0V
The inner shield
surrounding the
brake wires should
be earthed/grounded
at one point only.
The relays have normally open
contacts and are shown deactivated
(contacts open, brake engaged).
Figure 10 - Motor brake control circuit
This circuit uses the drive enable signal (configured using
DRIVEENABLEOUTPUT
to appear
on DOUT0) in conjunction with a brake output (configured using
MOTORBRAKEOUTPUT
to
appear on DOUT1). With this configuration, the following sequences can be used to control
the brake.
To engage the brake:
H
The motor is brought to rest under normal control;
H
Relay 2 is deactivated, causing the brake to engage;
H
The drive is disabled. This removes power from the motor and causes Relay 1 to be
deactivated.
To disengage the brake:
H
The drive is enabled, activating Relay 1;
H
Power is applied to the motor to hold position under normal control;
H
Relay 2 is activated, causing the brake to be disengaged.
It may be necessary to include a small delay, after Relay 2 has been activated, before starting
motion. This delay will allow time for the relay contacts to engage and the brake to release.
CAUTION
: The 24VDC power supply must be a separate supply as shown in Figure
10. Do not use the 24V supply powering the MintDrive
II
digital outputs, or
the internally generated supply (if present). The brake wires often carry
noise that could cause erratic drive operation or damage. The brake
contacts must never be wired directly to the digital outputs. The relay(s)
should be fitted with a protective flyback diode, as shown. The separate
24VDC supply used for the motor brake may also be used to power the
relay in the thermal switch circuit (section 3.5.5).
Содержание MDH1A05TB-RC23
Страница 1: ...MintDriveII Servo Position Control SERVO DRIVE Installation Manual 01 07 MN1901...
Страница 2: ......
Страница 14: ...www baldormotion com 2 4 Introduction MN1901...
Страница 94: ...www baldormotion com 6 10 Preset Moves PLC Task MN1901...
Страница 122: ...www baldormotion com A 10 Accessories MN1901...
Страница 130: ...www baldormotion com B 8 Control System MN1901...
Страница 158: ...www baldormotion com D 6 CE Guidelines MN1901...
Страница 164: ...www baldormotion com Comments MN1901 Thank you for taking the time to help us...
Страница 165: ......