www.baldormotion.com
1-4 General Information
MN1901
CAUTION
: Avoid locating the drive in the vicinity of corrosive substances or vapors, metal
particles and dust.
CAUTION
: Do not connect AC power to the drive terminals U, V and W. Connecting AC
power to these terminals may result in damage to the drive.
CAUTION
: Baldor does not recommend using “Grounded Leg Delta” transformer power leads
that may create earth/ground loops and degrade system performance. Instead,
we recommend using a four wire Wye.
CAUTION
: Drives are intended to be connected to a permanent main power source, not a
portable power source. Suitable fusing and circuit protection devices are required.
CAUTION
: The safe integration of the drive into a machine system is the responsibility of the
machine designer. Be sure to comply with the local safety requirements at the
place where the machine is to be used. In Europe these are the Machinery
Directive, the ElectroMagnetic Compatibility Directive and the Low Voltage
Directive. In the United States this is the National Electrical code and local codes.
CAUTION
: Drives must be installed inside an electrical cabinet that provides environmental
control and protection. Installation information for the drive is provided in this
manual. Motors and controlling devices that connect to the drive should have
specifications compatible to the drive.
CAUTION
: If the drive is subjected to high potential (‘hipot’) testing, only DC voltages may be
applied. AC voltage hipot tests could damage the drive. For further information
please contact your local Baldor representative.
CAUTION
: Violent jamming (stopping) of the motor during operation may damage the motor
and drive.
CAUTION
: Do not tin (solder) exposed wires. Solder contracts over time and may cause
loose connections. Use crimp connections where possible.
CAUTION
: Electrical components can be damaged by static electricity. Use ESD
(electro-static discharge) procedures when handling this drive.
CAUTION
: Ensure that resolver or encoder wires are properly connected. Incorrect
installation may result in improper movement.
CAUTION
: The threaded holes in the top and bottom of the enclosure are for cable clamps.
Be sure to use a M4 bolt no longer than 12mm in length. Longer bolts might
short-circuit the electrical components inside the drive.
CAUTION
: Removing the cover will invalidate UL certification.
Содержание MDH1A05TB-RC23
Страница 1: ...MintDriveII Servo Position Control SERVO DRIVE Installation Manual 01 07 MN1901...
Страница 2: ......
Страница 14: ...www baldormotion com 2 4 Introduction MN1901...
Страница 94: ...www baldormotion com 6 10 Preset Moves PLC Task MN1901...
Страница 122: ...www baldormotion com A 10 Accessories MN1901...
Страница 130: ...www baldormotion com B 8 Control System MN1901...
Страница 158: ...www baldormotion com D 6 CE Guidelines MN1901...
Страница 164: ...www baldormotion com Comments MN1901 Thank you for taking the time to help us...
Страница 165: ......