www.baldormotion.com
Input / Output 4-11
MN1901
4.3.4 Digital outputs - X3
Location
Connector X3
Pin Name
Mint keyword
18 DOUT0
OUTX.0
19 DOUT1
OUTX.1
20 DOUT2
OUTX.2
Description
Three general-purpose optically isolated digital outputs.
Output current: 50mA maximum each output
Update interval:
Immediate - Software (Mint programs)
2ms -
DRIVEENABLEOUTPUT
,
DRIVEOKOUTPUT
and
GLOBALERROROUTPUT
functions
Programmable - PLC Task functions
Each optically isolated PNP output is designed to source current from the USR V+ supply as
shown in Figure 33. The maximum saturated voltage across any of the outputs when active is
1.0VDC, so they can be used as TTL compatible outputs. If the outputs are used to directly
drive a relay, a suitably rated flyback diode must be fitted across the relay coil, observing the
correct polarity. This is to protect the output from the back-EMF generated by the relay coil
when it is de-energized. The outputs can be controlled directly using the Mint keyword
OUTX
(for example
OUTX.2=1
). The sense of the outputs can be configured in WorkBench v5, and
their states are displayed in the Spy window.
OUTX.
x
MintDrive
II
NEC PS2562L-1
Load
(Relay with
flyback diode
shown)
USR V+
DOUT0
6
18
‘X3’
CGND
8
Figure 33 - X3 digital output circuit - DOUT0 shown
18
20
CGND 8
Содержание MDH1A05TB-RC23
Страница 1: ...MintDriveII Servo Position Control SERVO DRIVE Installation Manual 01 07 MN1901...
Страница 2: ......
Страница 14: ...www baldormotion com 2 4 Introduction MN1901...
Страница 94: ...www baldormotion com 6 10 Preset Moves PLC Task MN1901...
Страница 122: ...www baldormotion com A 10 Accessories MN1901...
Страница 130: ...www baldormotion com B 8 Control System MN1901...
Страница 158: ...www baldormotion com D 6 CE Guidelines MN1901...
Страница 164: ...www baldormotion com Comments MN1901 Thank you for taking the time to help us...
Страница 165: ......