user some time to make the change without having to re-enter the security code. The amount of
time allowed is this Access Timeout parameter. The parameter sets the amount of time the user will
have to make changes without re-entering the security code. The amount of time is user
programmable and may be anywhere from 0-600 seconds. The programmed time starts upon
leaving the Program mode. The factory preset time is 0 seconds, which disables the Access
Timeout.
Access Code
- This parameter sets the security access code. If you choose to implement a
security access code be sure to write the number down in a secure location. The security access
code can be any number from 0000-9999. When changing the Access Code number parameter
the new number will not be displayed. The factory preset is 9999. If you cannot gain entry into the
security area to change a parameter. Please contact BALDOR. Be prepared to give the five digit
code located on the lower right hand side of the keypad display when prompted for a security code.
We can then assist in determining your access code number.
Motor Data Block
Motor Rated Amps
- Program in the motor's nameplate continuous rated current. This
parameter also sets the continuous output current to the motor. If the output current fed to the
motor exceeds the value in the Motor Rated Amps parameter for an extended period of time, the
control will trip off with an overcurrent or overload fault. The factory setting is the continuous current
rating of the control for the factory set operating zone.
Motor Poles
- Program in the number of motor poles. Factory setting is 4 poles. The listing below
is a table for standard Baldor BSM motors.
Resolver Speed
- This parameter sets the speed of the resolver. The range of resolver speeds that
can be selected are 0 - 10. The factory setting is 1 speed. All standard BSM motors use 1 speed
resolvers and this parameter would not normally need to be changed.
3-15
KEYPAD PROGRAMMING AND OPERATION
NUMBER OF
MOTOR
POLES
BSM63, BSM80
4
BSM90, BSM100
8
BSM4F, BSM6F,
8
BSM8F
BSM2R, BSM3R,
4
BSM4R
BSM6R
6
MN723H-10/95 11/28/95 1:11 AM Page 69 (Black plate)
Содержание 23H Series
Страница 11: ...1 8 GENERAL INFORMATION MN723H 10 95 11 28 95 1 07 AM Page 12 Black plate...
Страница 83: ...3 30 KEYPAD PROGRAMMING AND OPERATION MN723H 10 95 11 28 95 1 13 AM Page 84 Black plate...
Страница 99: ...4 16 DIAGNOSTIC INFO AND TROUBLESHOOTING MN723H 10 95 11 28 95 1 14 AM Page 100 Black plate...
Страница 125: ...5 26 APPENDIX G MN723H 10 95 11 28 95 1 21 AM Page 126 Black plate...
Страница 126: ...MN723H 10 95 11 28 95 1 21 AM Page 127 Black plate...