Page
118
The auxiliary inputs can be configured to provide accurate readings when connected to a fluid
temperature sensor by setting the auxiliary scale factor to a special code of 0. This tells the instrument
that the auxiliary input has been wired to a fluid temperature sensor (of the type the instrument has
been factor set for, such as type V, or type S as shown on the label on the rear cover). The EIS will
then convert the signal on the auxiliary input into a reading in degrees F or C according to the selection
on the UNITS page.
The user must install a resistor between the 4.8V output of the instrument, and the auxiliary input used
for the fluid temperature, and also connect the fluid temperature sensor to the aux input and ground.
The value of the resistor to be used is given in the following table.
Instrument sensor type as
shown on the rear cover. This
letter will appear in the
Software Version.
Value of 1% resistor to
connect between 4.8V
output and auxiliary input
S
475
V
301
7.1.5
Auxiliary Forward/Reverse Sensing Selection (+/-)
This selection tells the instrument whether each auxiliary input will be sensed forward (increasing
voltage = increasing value) or reverse (increasing voltage = decreasing value). The sheet included with
the auxiliary input sensor will tell you if forward or reverse is required. In most cases, forward sensing
is used.
This page displays all 6 forward/reverse selections on one page. Use the left and center buttons to
select the combination that fits your needs. The +/- signs apply, from leftmost to rightmost, auxiliary
1 to auxiliary 6 respecitively. The following screen shows auxiliary 2 set to reverse sensing, with all
other inputs set to forward sensing.
+ / - + - + + + +
U P D O W N N E X T
7.1.6
Auxiliary Decimal/Integer Selection (D/I)
This selection allows you to chose whether the display includes a decimal point before the last digit
(the D selection), or not (the I selection). The decimal selection is useful for displaying such values as
Manifold Pressure (inches and tenths of inches of mercury), or possibly fuel level (gallons and tenths
of gallons). Integer values are typically used for most auxiliary input functions, including fuel pressure,
coolant pressure, ammeter etc. As with the Forward/Reverse sensing function, the leftmost D or I
character on the right of the screen applies to auxiliary 1, and the rightmost to auxiliary 6. Use the UP
and DOWN buttons to select the desired combination.
Содержание 912 Dragonfly
Страница 3: ...Page 2 ...
Страница 4: ...Page 3 ...
Страница 5: ...Page 4 ...
Страница 25: ...Page 24 Drawing 1 ...
Страница 27: ...Page 26 Drawing 2 ...
Страница 29: ...Page 28 Drawing 3 ...
Страница 31: ...Page 30 Drawing 4 ...
Страница 33: ...Page 32 Drawing 5 ...
Страница 35: ...Page 34 Drawing 6 ...
Страница 37: ...Page 36 Note for Hydraulic Brakes see Appendix B Drawing 7 ...
Страница 39: ...Page 38 Drawing 8 ...
Страница 41: ...Page 40 Drawing 9 ...
Страница 43: ...Page 42 Drawing 10 ...
Страница 45: ...Page 44 Drawing 11 ...
Страница 47: ...Page 46 Drawings 12A 12B ...
Страница 49: ...Page 48 Drawing 13 ...
Страница 51: ...Page 50 Drawing 14 ...
Страница 53: ...Page 52 Drawing 15 ...
Страница 55: ...Page 54 Drawing 16 ...
Страница 57: ...Page 56 Drawing 17 ...
Страница 59: ...Page 58 Drawing 18 ...
Страница 61: ...Page 60 Drawing 19 ...
Страница 63: ...Page 62 Drawing 20 ...
Страница 65: ...Page 64 Drawing 21 ...
Страница 67: ...Page 66 Drawing 22 ...
Страница 69: ...Page 68 Drawing 23 ...
Страница 71: ...Page 70 Drawing 24 ...
Страница 73: ...Page 72 Drawing 25 ...
Страница 75: ...Page 74 Drawing 26 ...
Страница 77: ...Page 76 Drawing 27 ...
Страница 79: ...Page 78 Wiring1 jpg Drawing 28a ...
Страница 80: ...Page 79 Wiring2 jpg Drawing 28b ...
Страница 81: ...Page 80 elecLights jpg Drawing 28c ...
Страница 83: ...Page 82 Drawing 29 ...
Страница 85: ...Page 84 Drawing 30 ...
Страница 92: ...Page 91 Appendix B Brakes Manual for BX1320 BX1000 Appendix B Page 1 ...
Страница 93: ...Page 92 Appendix B Page 2 ...
Страница 94: ...Page 93 Appendix B Page 3 ...
Страница 96: ...Page 95 Appendix B Page 5 ...
Страница 97: ...Page 96 Appendix B Page 6 ...
Страница 98: ...Page 97 Appendix B Page 7 ...
Страница 104: ...Page 103 Figure 1a Description of Display Pages ...
Страница 105: ...Page 104 Figure 1b Description of Display Pages ...
Страница 138: ...Page 137 Appendix C EIS 4000 912 914 ...
Страница 139: ...Page 138 Appendix C EIS 4000 912 914 ...
Страница 140: ...Page 139 Appendix C EIS 4000 912 914 ...
Страница 141: ...Page 140 Appendix C EIS 4000 912 914 End Appendix C ...
Страница 155: ...Page 154 Appendix E2 Powerfin Prop Page 2 ...
Страница 156: ...Page 155 Appendix E2 Powerfin Prop Page 3 ...
Страница 157: ...Page 156 Appendix E2 Powerfin Prop Page 4 ...
Страница 158: ...Page 157 Appendix E2 Powerfin Prop Page 5 ...
Страница 159: ...Page 158 Appendix E2 Powerfin Prop Page 6 ...
Страница 160: ...Page 159 Appendix E2 Powerfin Prop Page 7 ...
Страница 161: ...Page 160 Appendix E2 Powerfin Prop Page 8 ...
Страница 162: ...Page 161 Appendix E2 Powerfin Prop Page 9 ...
Страница 163: ...Page 162 Appendix E2 Powerfin Prop Page 10 ...
Страница 164: ...Page 163 Appendix E2 Powerfin Prop Page 11 End of Appendix E2 ...
Страница 187: ...Page 186 By Memphis Soaring FIGURE 3 Common Signals ...