background image

BA-440 DualBeam Barcode Reader Quickstart Guide Ver 5

14. Install and seal the reader Hood

Set the Hood in place over the top of the BA-440 decoder assembly so that the six studs pass into the six holes on the baseplate. The front 
window of the Hood goes by the gold polygon as shown. Secure the Hood using the six 11/32” flanged nuts from the hardware bag. The 
Hood must be secured using all 6 flanged nuts for a good seal. 

IMPORTANT: Thread all 6 nuts finger tight first, then tighten only 1/4 to 1/2 turn more on each nut.

CAUTION: The seal on the reader Hood and hardware may be damaged if nuts are overtightened.

To prevent unauthorized access a padlock (not included) may be placed through lock tab at the rear of the BA-440.

Bottom View 

Lock Tab at 

Rear of Baseplate 

Thread all six flanged nuts 
finger tight first; then tighten 
only 1/4 to 1/2 turn more to  
secure Hood in place 

Assembly complete.  

Contact BAI at 800-528-9167 with 

any questions. 

Содержание BA-440 DualBeam

Страница 1: ...not matter which side of the road it is mounted on as long as the vehicle decals are on the same side Always place the reader and decals on the same side of the car Typical Installation Position Mount...

Страница 2: ...ver with 1 8 blade Wire stripper 4 Unpack Reader Remove Decoder Module box Hardware and Accessories box and Reader Enclosure from the shipping box Take Reader Enclosure from bag and flip upside down R...

Страница 3: ...6 Seal wiring port in Baseplate Once the wiring is run up the mounting post and out through the hole in the Baseplate you can use the 4 putty roll from the hardware bag to seal the opening in the bas...

Страница 4: ...he gold polygon This gold polygon should face the road with the terminal block for connections at the rear of the Baseplate Use the four 5 16 nylock nuts on the threaded studs to secure the decoder mo...

Страница 5: ...DC source 24V POWER INPUT Positive input from 24VDC source GdRead RELAY OUTPUT Gate normally open NO GdRead RELAY OUTPUT Gate normally open NO Aux In INPUT for Vehicle presence trigger Aux In INPUT fo...

Страница 6: ...ly 5Vdc present on the Data0 and Data1 terminals If the voltage is present communications should operate fine 11 Convert to Direct Wiegand connection if Optoisolated connection does not function Direc...

Страница 7: ...n a short beep from the BA 440 and data transmission out both the serial port and Wiegand port Decal should read out to at least 6 out from the reader NOTE You must wait at least 1 second after a read...

Страница 8: ...ck the voltage on Data 0 and Data 1 to see if there is 5 VDC present If no voltage is found or if voltage is less than 3 Vdc Wiegand messages cannot be sent Be sure the access system is connected and...

Страница 9: ...the test circuit is live for 10 minutes after you turn the test switch ON then it will go into hibernation This is to preserve battery life if the technician forgets to turn the test circuit off To re...

Страница 10: ...be secured using all 6 flanged nuts for a good seal IMPORTANT Thread all 6 nuts finger tight first then tighten only 1 4 to 1 2 turn more on each nut CAUTION The seal on the reader Hood and hardware m...

Отзывы: