Fyrite INSIGHT
43
4.14 Printing Test Data
Combustion, pressure, smoke number or temperature data that is currently
being displayed can be sent to a printer using IrDA protocol as described
below.
Data that is stored in memory can also be printed by first displaying the
stored test data as described in Section 4.13.
In addition to printing combustion, pressure, and temperature data, the
contents of any screen that shows the label “PRINT” above the
F1
button
can be printed. For example, the information shown in the DIAGNOSTIC
screen can be printed.
1. Power up the printer. Refer to the printer’s instruction manual for
detailed operating information. If not previously done, select the follow-
ing for the printer for:
• 8 bit
• No parity
• 9600 baud
• IrDA is set to IrDA-
SIR
• DTR handshak
-
ing
2. Align the printer with
the top of the ana-
lyzer.
3. Press the
PRINT (F1)
button to begin print-
ing.
F1
F2
F3
ESC
RUN
HOLD
PWR
BACHARACH, INC.
Fyrite Insight
SN: 1234-5678
Time: 10:28:38
Date: 09/01/09
Fuel
NGAS
O
2
4.0 %
CO
11 ppm
LAMBDA 1.23 %
CO
2
9.5 %
CO
2
Max 11.8 %
T-STK
190
o
C
T-AIR
22.3
o
C
qA
8.0 %
Eta
92.0%
Eff
82.4%
CO/CO2 0.0001%
CO(O)
13 ppm
AVG SMOKE ***
OIL DERIVE ***
BOILER TEMP ***
o
C
Comments:
Fig. 4.2