Fyrite INSIGHT
22
The default order in which data is displayed is listed below.
O
2
=
Oxygen
CO
=
Carbon Monoxide
LAMBDA
=
Excess air
CO
2
=
Carbon Dioxide
CO
2
Max
=
% CO
2
in flue gas assuming perfect combustion
T-STK
=
Stack Temperature
T-AIR
=
Ambient/Primary Air Temperature
qA
=
Stack loss
Eta
=
Efficiency referenced to the lower heating value
Eff
=
Efficiency referenced to the higher heating value
CO/CO
2
=
Carbon Monoxide/Carbon Dioxide
CO(n)
=
Carbon Monoxide content referenced to % O
2
AVG SMOKE =
Average of 3 manually entered smoke numbers
OIL DERIVE =
Manually entered Yes or No
BOILER TEMP
=
Boiler temperature manually entered
NOTE:
(n) is the current O
2
Reference selected.
Changing the data display order:
1. Access the Setup Menu per Section 3.7.
2. Select
Run/Hold Format
.
A screen will appear that displays the Edit Format and Reset Format op-
tions.
• Press ▲▼ buttons to scroll/highlight options.
• Press
(
ENTER
)
to select
or save.
•
Press
ESC
to go back.