Version 3.0.0 Preliminary Documentation – May be Subject to Change 18-46
Subindex 4h
Description Save
manufacturer
parameters
Access RW
PDO Mapping
No
Value Range
0x65766173
(write access)
1h
(read access)
Default Value
1h (saves parameters on command)
3.1.6. Object 1011h: Restore Default Parameters
This object supports the restoring of the default values for the object dictionary in non-
volatile memory. In order to avoid restoring of parameters by mistake, the device restores
the defaults only when a specific signature is written to the appropriate subindex. The
signature is “load”.
The signature is a 32-bit unsigned number, composed of the ASCII codes of the signature
characters, according to the following table:
MSB
LSB
d a o l
64h 61h 6Fh 6Ch
On reception of the correct signature to an appropriate subindex, the 18 Digital Input will
restore the defaults in non-volatile memory, and then confirm the SDO transmission. The
default values are set valid after the device is reset or power-cycled.
By read access, the object provides information about the module’s default parameter
restoring capabilities.
Object Description
Index 1011h
Name
Restore Default Parameters
Object Type
ARRAY
Data Type
UNSIGNED32
Entry Description
Subindex 0h
Description
Largest subindex supported
Access RO
PDO Mapping
No
Value Range
4
Default Value
4
Subindex 1h
Description
Restore all default parameters
Access RW
PDO Mapping
No
Value Range
0x64616F6C
(write access)
1h
(read access)
Default Value
1h (restores defaults on command)
Subindex 2h
Description
Restore default communication parameters
Access RW
PDO Mapping
No