128
At present, only the
“WAV” audio file format is supported.
Step 13. To enable alarm sound playback, click
“Start Alarm Sound (System)” icon
(this functions as the main switch
– will become grayed-out).
To shut off alarm sound playback before the time set has elapsed (duration), click
“Stop Alarm Sound (System)” icon (will become grayed-out).
C.2 Alarm Sound Setup for No Audio Occurrence
Step 1. Select
“On” in “Alarm”
”Enable” to enable the various alarm features.
Step 2. Select
“On” in “Audio Alarm”
”Enable” to enable audio loss detection to be monitored on a
single channel or group.
Step 3. Select
“On” in “No Audio Alarm (Single Meter)” to enable the alarm that is triggered when no
audio signal is detected on any of the meters enabled (with checkmark) in
“Set Meter” dialog
box (refer to step 9).
Step 4. Set the
“Signal In/Out” alarm “Response Time,” such as when inputting the signal or change of
status from “abnormal” to “normal.” If the Audio Alarm is activated, but the signal is restored,
then the alarm will be cancelled after the amount of time set for “Signal In”. If the Audio Alarm is
triggered, the alarm will be activated after the amount of time set for “Signal Out.”