3.4 Service Menu
Table 3: SMA protocol
Command Sent to Indicator
Result
<LF>W<CR>
Weight returned if no motion. Dashes displayed if motion on scale.
<LF>P<CR>
Weight returned if no motion. Dashes displayed if motion on scale.
<LF>Z<CR>
Scale zeros itself if no motion. Dashes displayed if motion on scale.
<LF>T<CR>
Scale tares itself and returns G or N weight if no motion. Dashes displayed if motion on scale.
<LF>T<xxxxxx.xxx><CR>
Scale attempts to take the <xxxxxx.xxx> data as the tare weight and returns G or N weight if no
motion. Dashes displayed if motion on scale.
<LF>M<CR>
Returns the tare weight if no motion. Dashes displayed if motion on scale.
<LF>C<CR>
Clears the tare weight if no motion. Dashes displayed if motion on scale.
<LF>U<uuu><CR>
Sets the unit of measure label to uuu Example: lb_ ( _ =space) Works for lb or kg only, not
custom units
<LF>D<CR>
Runs scale diagnostics and sends diagnostic message
<LF>A<CR>
Sends the SMA compliance level. See note at left.
<LF>B<CR>
1st B sent returns manufacturer
2nd B sent returns model software #
3rd B sent returns the software revision level
4th B sends an END
5th or more sends a ?
<LF>U<CR>
Toggles the units of measure if no motion. Dashes displayed if motion on scale.
<LF>I<CR>
Sends the SMA compliance level as
SMA:compliance level / revision level
<LF>N<CR>
1st N sends the scale type;
S
or
C
.
TYP:S
= scale,
TYP:C
= Classifier
2nd N sends
CAP:uuu:c..c:n:d
where
uuu
= unit of measure
c..c
= full capacity of this range. If multi-interval is not enabled, this is the scale capacity.
n
= Least significant count-by digit
d
= decimal point position:
0 = none
1 = XXXX.X
2 = XXX.XX
3 = XX.XXX…etc.
3rd N sends the following if multi-interval is enabled: the same info as the 2nd N except for the
upper range of the multi-interval.
3rd N sends the following if the multi-interval is disabled: List of the SMA level 2 commands that
are implemented:
CMD:PTMCU
Last valid N sends
END
Subsequent N commands will return a ‘?’ response.
ESC
This reboots the indicator
<LF>XP<num><CR>
Request a print format to be printed, 0-10
<LF>XT<cutoff><xxxx.xx><CR>
Set a cutoff/trip weight.
Attempts the take <xxxx.xx> as the weight for cutoff #<cutoff>. The indicator will respond with:
<LF>XT<cutoff><xxxx.xx>Set<CR> if the cutoff weight was accepted or <LF>XTFail<CR> if the
cutoff weight could not be set to the value specified. Cutoff =1-3. Weight limited to scale cap.
Содержание E1070
Страница 1: ...Model E1070 Indicator Service Manual NORTH AMERICA AWT35 500106 Issue AF March 2010 ...
Страница 6: ...6 E1070 Service Manual ...
Страница 51: ...E1070 Service Manual 51 3 4 Service Menu Table 3 1 Printalbe Characters Chart ...
Страница 146: ...146 E1070 Service Manual 8 Network Connections ...
Страница 149: ...E1070 Service Manual 149 10 Complete Menu Structures 10 1 Complete Supervisor and User Menus Supervisor Menu User Menu ...
Страница 150: ...150 E1070 Service Manual 10 2 Complete Service Menu ...
Страница 153: ...E1070 Service Manual 153 11 3 Wall Mount Application ...
Страница 154: ...154 E1070 Service Manual 11 4 System Block Diagram ...
Страница 155: ...E1070 Service Manual 155 11 5 Keypad Schematic and Power Supply Bd P N 60071 0016 ...
Страница 158: ...158 E1070 Service Manual 11 8 I O External Calbe Identification Pin outs ...
Страница 162: ...162 E1070 Service Manual ...
Страница 163: ......