134
E1070 Service Manual
4
SensorComm Hardware Configuration and Calibration
4.4
CAL submenu for SensorComm scales
If your system is set up for a SensorComm j-box, the shaded portion of the calibration
menu is the first item. See Figure 15. Follow these steps to corner the system and then
continue on with the calibration procedures outlined in CAL submenu for analog scales.
Figure 4.1 SensorComm cornering menu
1.
Access the Service menu…
CAL
is displayed.
4.4.1 CORNER (SensorComm Cornering)
2.
Press the
key…
COrnEr
is displayed. Use this item to corner the SensorComm system.
3.
Press the
key…
dLoAd
is displayed. This stands for deadload.
4.
Press the
key…
Numeric entry screen is displayed.
5.
Key in the size of your cornering (test) weight. Press the
ENTER
key to enter
this value and to record the deadload weight…
buSY
is briefly displayed and then
dLoAd
is displayed.
Содержание E1070
Страница 1: ...Model E1070 Indicator Service Manual NORTH AMERICA AWT35 500106 Issue AF March 2010 ...
Страница 6: ...6 E1070 Service Manual ...
Страница 51: ...E1070 Service Manual 51 3 4 Service Menu Table 3 1 Printalbe Characters Chart ...
Страница 146: ...146 E1070 Service Manual 8 Network Connections ...
Страница 149: ...E1070 Service Manual 149 10 Complete Menu Structures 10 1 Complete Supervisor and User Menus Supervisor Menu User Menu ...
Страница 150: ...150 E1070 Service Manual 10 2 Complete Service Menu ...
Страница 153: ...E1070 Service Manual 153 11 3 Wall Mount Application ...
Страница 154: ...154 E1070 Service Manual 11 4 System Block Diagram ...
Страница 155: ...E1070 Service Manual 155 11 5 Keypad Schematic and Power Supply Bd P N 60071 0016 ...
Страница 158: ...158 E1070 Service Manual 11 8 I O External Calbe Identification Pin outs ...
Страница 162: ...162 E1070 Service Manual ...
Страница 163: ......