RJ45 to DB-9 cable, or a DB-9 to RJ45 adapter to connect the switch console port to your
management terminal. The maximum length of a console cable is 25 feet (8.3 meters). The
following figure and table describe the RJ45 console port pin-out information. You can use the
pin-out information to verify or create a console cable for use with your maintenance
terminal.
Figure 28: RJ45 console port pin-out
Table 2: Console port pin-out
RJ45 console port pin-
out
Signal
Requirement
1
RTS (ready to send)
Optional (can be swapped or linked
with pin 8)
2
DTR (data terminal
ready)
Optional
3
TXD (transmit data)
Mandatory
4
DCD (carrier detect)
Optional
5
GND (ground)
Mandatory
6
RXD (receive data)
Mandatory
7
DSR (data set ready)
Optional
8
CTS (clear to send)
Optional (can be swapped or linked
with pin 1)
Out of Band Management port
The Out of Band Management port is the RJ45 port directly below the console port. The port
is labelled management, and can support 10/100/1000 Ethernet connections. The Out of Band
Management port is available for use when the switch is running diagnostic or agent software.
You can use the Out of Band Management port to perform an emergency TFTP download of
diagnostic or agent software to the switch. When performing a TFTP download, an IP address
is temporarily assigned to the management port which enables the switch to receive files from
the TFTP server.
When the switch is running agent software, you can use the Out of Band Management port
configured with an out of band management IP and gateway for remote management. For
Preparations for network connectivity
58 VSP 7000 installation
July 2013
Содержание VSP 7000 Series
Страница 4: ...4 VSP 7000 installation July 2013 Comments infodev avaya com ...
Страница 6: ...Installing an MDA 66 Appendix A Hardware reliability 67 6 VSP 7000 installation July 2013 ...
Страница 19: ...Figure 1 Fan trays Figure 2 AC power supply Cooling fans and power supplies VSP 7000 installation July 2013 19 ...
Страница 28: ...Installation preparation 28 VSP 7000 installation July 2013 Comments infodev avaya com ...
Страница 56: ...Fabric Interconnect connectivity 56 VSP 7000 installation July 2013 Comments infodev avaya com ...
Страница 68: ...Hardware reliability 68 VSP 7000 installation July 2013 Comments infodev avaya com ...