Chapter 5: Switch installation
Switch placement options
You can install the switch in an equipment rack using the brackets provided. The included
brackets allow for two-post equipment rack front mount or rear mount installations. If you are
installing the switch into a four-post equipment rack, you can use an optional four-post
extended bracket kit (sold separately).
You can also install a single switch on any flat surface that can safely support the weight of
the switch and attached cables. A switch with two power supplies installed weighs
approximately 27 lbs (12.25 kg). Cable weight varies for each installation.
Ensure the area where you install and use the switch meets all environmental requirements.
Environmental requirements
The following list describes the requirements for the switch environment.
• ambient temperature between 32°F and 122°F (0°C and 50°C)
• relative humidity between 0% and 95% non-condensing
• altitude of –200 to 13,000 feet
• acoustic noise less than 50dBA typical
• no nearby heat sources such as hot air vents or direct sunlight
• no nearby sources of severe electromagnetic noise
• no excessive dust
• adequate power source within six feet; one circuit required for each power supply
• at least 2 inches (5.08 cm) on all sides of the switch unit for ventilation
• adequate space at the front and rear of the switch for access to cables
Note:
The switch supports thermal protection and immediately shuts down if the internal
temperature reaches 185°F (85°C).
The switch software monitors the internal temperature and generates log and SNMP traps
to indicate that the switch is running above the high temperature threshold and is
approaching a critical over temperature fault.
VSP 7000 installation
July 2013 29
Содержание VSP 7000 Series
Страница 4: ...4 VSP 7000 installation July 2013 Comments infodev avaya com ...
Страница 6: ...Installing an MDA 66 Appendix A Hardware reliability 67 6 VSP 7000 installation July 2013 ...
Страница 19: ...Figure 1 Fan trays Figure 2 AC power supply Cooling fans and power supplies VSP 7000 installation July 2013 19 ...
Страница 28: ...Installation preparation 28 VSP 7000 installation July 2013 Comments infodev avaya com ...
Страница 56: ...Fabric Interconnect connectivity 56 VSP 7000 installation July 2013 Comments infodev avaya com ...
Страница 68: ...Hardware reliability 68 VSP 7000 installation July 2013 Comments infodev avaya com ...