![Avaya Call Management System Скачать руководство пользователя страница 119](http://html1.mh-extra.com/html/avaya/call-management-system/call-management-system_custom-reports_3028118119.webp)
Test Design Error Messages
Issue 3.0 May 2002
119
Test Design Error Messages
Test design error messages are divided into three categories:
●
Phase 1 Error Messages (detected before the sample input screen is displayed)
●
Phase 2 Historical Error Messages (require the sample input before occurring)
●
Phase 2 Real-Time Error Messages (require the sample input before occurring).
Phase 1 error messages
Test design error messages contains Phase 1 error messages. The following table lists the
messages alphabetically and includes a cause and a recommended solution for each
message.
Phase 1 error messages
Message:
$<variable name> not defined
Cause:
The “where” clause contains a variable that is not defined.
Solution:
Define the variable using the define input action or remove
the variable from the row search criteria.
Message:
Cannot mix aggregates and nonaggregates in the select
Cause:
You specified both aggregate columns and nonaggregate
columns in the same select for real-time reports.
Solution:
Create two identical row search conditions and apply one to
the aggregate columns and one to the nonaggregate
columns.
Message:
Cannot use the SYN function for order by
Cause:
You tried to use a synonym to sort the output.
Solution:
Remove the SYN aggregate from the
Order by
field.