60
8-2 Display error code of outdoor unit's indicator lights
Display by the 3 LED indicator lights on the PCB of the outdoor unit:
○ for off; ● for on;
★
for flashing.
No
.
LE
D1
LE
D2
LE
D3
Error Name
Probable Trouble Location
1
○
○
○
Normal (outdoor
unit standby)
Normal, all three lights off for standby
status.
2
★
★
★
Normal
(compressor
running)
Normal, all three lights flash while
compressor running.
3
●
●
●
Forced service
(test mode)
Normal
4
★
★
●
Module
protection error
Power voltage, compressor cable, reactor,
module panel, Outdoor Unit main PCB,
compressor.
5
★
★
○
PFC protection
error
Power voltage, reactor, module panel,
Outdoor Unit main PCB.
6
★
●
★
Compressor
out-of-step error
Power voltage, compressor cable, module
panel, Outdoor Unit main PCB,
compressor.
7
★
○
★
Exhaust air sensor
error
System pressure, exhaust air sensor,
Outdoor Unit main PCB.
8
●
★
★
Outdoor Unit coil
sensor error
Outdoor Unit coil sensor, Outdoor Unit
main PCB.
9
○
★
★
Outdoor Unit
room temperature
sensor error
Outdoor Unit room temperature sensor,
Outdoor Unit main PCB.
10
★
●
●
Indoor and
outdoor unit
communication
error
Connection wire, Indoor Unit main PCB,
Outdoor Unit main PCB, EE reverse
connection, module panel.
11
★
●
○
Outdoor Unit
main PCB and
module panel
communication
error
Connection wire of module and main
control data, module panel, Outdoor Unit
main PCB
12
★
○
●
Outdoor EE error Outdoor Unit main PCB
13
★
○
○
Outdoor DC
motor error
Mechanical jam of Outdoor Unit motor,
Outdoor Unit DC motor, Outdoor Unit
main PCB.
Содержание ASW-H09B5B4/FAR3DI-C3
Страница 1: ...AUX Imp Exp Company Limited F Freedom Inverter Split Type Air Conditioner ...
Страница 2: ...This manual is for professional maintenance personnel only ...
Страница 4: ...1 Part I Technical Information 1 Summary 1 1 Appearance Indoor Unit FZ Outdoor Unit 09K 12K 18K 24K ...
Страница 7: ...4 2 2 Outdoor Unit 1 3P 1 8P 新 2P 2 3P ...
Страница 17: ...14 5 Electrical Part 5 1 Wiring Diagram Indoor Unit 09K 12K 18K 24K Outdoor Unit 09K 12K ...
Страница 18: ...15 18K 24K ...
Страница 19: ...16 Part II Installation and Maintenance 6 Main Tools for Installation and Maintenance ...
Страница 71: ...68 Remote Control Can Not Work Trouble shooting procedure ...
Страница 72: ...69 9 Exploded Views and Parts List 9 1 Indoor Unit ...
Страница 74: ...71 9 2 Outdoor Unit ...
Страница 77: ...74 3 Remove air louver 4 Remove air filter 5 Remove Medium frame wiring cover ...
Страница 78: ...75 6 Remove medium frame 7 Remove Control the lid 8 Remove Electric box ...
Страница 79: ...76 9 Remove press plate 10 Remove component 11 Remove pipe clamp ...
Страница 80: ...77 12 Remove evaporator 13 Remove the blade 14 Remove Motor press plate ...
Страница 81: ...78 15 Remove Motor 10 2 Outdoor Unit Part Procedure Diagram 1 Outdoor unit ...
Страница 82: ...79 2 Remove top cover 3 Remove control box cover ...
Страница 83: ...80 4 Remove panel grille 5 Remove front panel ...
Страница 84: ...81 6 Remove E part cover 7 Remove right side panel ...
Страница 85: ...82 8 Remove axial flow blade 9 Remove outer motor ...
Страница 86: ...83 10 Remove electric box assy 11 Remove motor support ...
Страница 87: ...84 12 Remove reactor 13 Remove partition board ...
Страница 88: ...85 14 Remove left side support plate 15 Remove pipeline assembly ...
Страница 89: ...86 16 Remove stop valve assembly 17 Remove valve plate ...
Страница 90: ...87 18 Remove compressor 19 Remove condenser ...