8
Which enables you to select different operation mode, after each pressing, the
operation mode will be changed. It shows in the following display.
AUTO → COOL→ DRY → HEAT→ MOTOR→ AUTO
Remark : cold wind type has no heating function.
11.
“
SLEEP
”
button
1. Press the SLEEP button, the sleeping indicator light of indoor unit flashes on.
2.After the setting of sleeping mode, the cooling operation enables the set temperature
to increase 1
℃
after 1hour and another 1
℃
automatically after 1 hour.
3.After the setting of sleeping mode, the heating operation enables the set temperature
to drop 1
℃
after 1hour and another 2
℃
automatically after 1 hour.
4. The air-conditioner runs in sleeping mode for 7 hours and stops automatically.
Remark : press the MODE or ON/OFF button the remote, the remote controller
clears sleeping mode away.
12. “SWING” button
Press this button, the horizontal wind direction vanes can swing automatically, when
you have the desired vertical wind direction, press it again, the horizontal wind
direction vanes will be stopped at the situation of your choice.
13.
“
SLEEP
”
button
Press this button you can turn on or off the health function.
14.
“
FUNGUSPROOF
”
button
This A/C has special dry and anti-mold function which has “yes” or “no” two
selections. This function is controlled by the remote controller under cooling, dry and
auto (cooling and dry) modes, the horizontal wind guiding bars are at the initial
position for cooling. The A/C runs under heating mode (the cooling only A/C only
runs under fan mode), the Indoor Unit motor runs for three minutes with weak wing
before stop. The purpose of this function is to dry the inside of the evaporator and to
prevent the evaporator from going mouldy due to water deposition and thus dispersing
strange smell.
Note :
1. This function has not been set in the factory. You may freely set and cancel this
function. The setting method is: under “off ” status of the A/C and the remote
Controller, point the remote controller toward the A/C and continuously press
"FUNGUSPROOF" push button for one time, the buzzer keep beeping five
times again after five times beep, indicating that this function is ready. In case
this function has been set, unless the whole A/C is powered off or the function is
manually cancelled, the A/C then has this function as default;
2. To cancel the function :
①
Power off the whole A/C;
②
Under “off ” status of the A/C
and the remote controller, point the remote controller toward the A/C and continuously press
“FUNGUSPROOF” push button for one time, the buzzer keep beeping three times again after
five times beep, including that this function has been cancelled;
3. When this function is on, it is suggested not to restart the A/C before it is completely stop;
4. This function will not run in case of time stop or sleep stop.
2)
Introduction for mode settings
Содержание ASW-H09B5B4/FAR3DI-C3
Страница 1: ...AUX Imp Exp Company Limited F Freedom Inverter Split Type Air Conditioner ...
Страница 2: ...This manual is for professional maintenance personnel only ...
Страница 4: ...1 Part I Technical Information 1 Summary 1 1 Appearance Indoor Unit FZ Outdoor Unit 09K 12K 18K 24K ...
Страница 7: ...4 2 2 Outdoor Unit 1 3P 1 8P 新 2P 2 3P ...
Страница 17: ...14 5 Electrical Part 5 1 Wiring Diagram Indoor Unit 09K 12K 18K 24K Outdoor Unit 09K 12K ...
Страница 18: ...15 18K 24K ...
Страница 19: ...16 Part II Installation and Maintenance 6 Main Tools for Installation and Maintenance ...
Страница 71: ...68 Remote Control Can Not Work Trouble shooting procedure ...
Страница 72: ...69 9 Exploded Views and Parts List 9 1 Indoor Unit ...
Страница 74: ...71 9 2 Outdoor Unit ...
Страница 77: ...74 3 Remove air louver 4 Remove air filter 5 Remove Medium frame wiring cover ...
Страница 78: ...75 6 Remove medium frame 7 Remove Control the lid 8 Remove Electric box ...
Страница 79: ...76 9 Remove press plate 10 Remove component 11 Remove pipe clamp ...
Страница 80: ...77 12 Remove evaporator 13 Remove the blade 14 Remove Motor press plate ...
Страница 81: ...78 15 Remove Motor 10 2 Outdoor Unit Part Procedure Diagram 1 Outdoor unit ...
Страница 82: ...79 2 Remove top cover 3 Remove control box cover ...
Страница 83: ...80 4 Remove panel grille 5 Remove front panel ...
Страница 84: ...81 6 Remove E part cover 7 Remove right side panel ...
Страница 85: ...82 8 Remove axial flow blade 9 Remove outer motor ...
Страница 86: ...83 10 Remove electric box assy 11 Remove motor support ...
Страница 87: ...84 12 Remove reactor 13 Remove partition board ...
Страница 88: ...85 14 Remove left side support plate 15 Remove pipeline assembly ...
Страница 89: ...86 16 Remove stop valve assembly 17 Remove valve plate ...