AUX DC Inverter 1 Drive1 50HZ R410A
Sensorresistance table
126
5.
“HEAT”button
*Pressthe
HEAT
button,youcandirectlyentercooling mode.
Note:
cooling onlyunit hasno heatingfunction.
6.
“SWING”button (SWING←→ andSWING↑↓)
*Pressthis buttonto startup/down(left/right) swingfunction, press itagain,fixlouver position.
*Up/down(left/right)settingisonlyvalidinthismode;itwill not affectlouver positioninothermodes.
*Up/down (left/right)swing hasmemoryfunction, itcan keepprimarysettingwhen turn offthenturnon
orswitchfromothermodesto primarymode.
7. “HEALTH” button
* Press this button; you can turn on or off the health function.
8. “SLEEP” button
* Press SLEEP button, the sleeping indicator light of indoor unit flashes on.
* The air-conditioner runs in sleeping mode for 10 hours and quiet sleep mode, recover back to former
mode.
* The unit will turn off automatically if the timing mode is running out of time.
* Note: press the MODE or ON/OFF button, the remote controller clears sleeping mode away.
9. “iFEEL” button
* Press this button to set “iFEEL”function. The LCD shows the actual room temperature when the
function set and it shows the setting temperature when the function cancelled.
* This function is invalid at Fan mode.
10.“DISPLAY” button
* In display mode, press button once, switch off “DISPLAY”, Press “DISPLAY” again, LCD will show
ambient & setting temperature after flashing 5s. It's convenient for users to check ambient or setting
temperature at any time in darkness.
11.“iCLEAN” button
* When remote controller is at the off state, press this
button, the unit runs“iCLEAN”function .
* The purpose of this function is to clean dust on evaporator and dry the inside water of evaporator and
to prevent theevaporator going moldy due to water deposition and boasting strange smell.
* After setting “iCLEAN” function, press“iCLEAN”buttonor“ON/OFF”button to quit.
* The clean function will stop working after about 30 minutes running without any operation.
12.
“ELE.H”button(forauxiliaryelectricheatingIDU)
*In heatingmode,pressthisbutton,
auxiliary
electric heatingwillwork.
13
.“Anti-FUNGUS”button
* The purpose ofthisfunctionisto drytheinsideofthe evaporatorandtopreventthe
evaporatorfrom going mouldyduetowater deposition andthus dispersing strangesmell.
* To operatethefunction:under
“off” status oftheA/Cand
Theremotecontroller,press
“
Anti-UNGUS
”button for
Onetime,thebuzzer keepbeepingfivetimesagain after five timesbeep, indicatingthatthe
functionisready.
* To cancel the function:1.unde
r“OFF”statusof theA/Cand
theremotecontroller,press
“
Anti-FUNGUS
”buttonagain.
14
.“SPOTSWING”button
*Pressthisbutton,thehorizontalwind directionvanescanswingautomatically,whenyou have the desired
vertical wind direction.
*Press
“
SPOT SWING
”again,thehorizontal winddirectionvaneswill bestoppeddependonyou.
15
.“ECO”button
*In coolingmode, pressthisbutton,theunitwillrun“
ECO
” economic operationmodewhichtakestheleast
power consumption.
*Afterrunning for 8h,itwill automatically quit.Youcan press
“
ECO
”buttononceagaintoquit.
Содержание AMCA-H09/4R1A
Страница 1: ...AUX DC Inverter Free Match 50HZ R410A 1 SERVICE MANUAL DC Inverter Free Match R410a ...
Страница 28: ...AUX DC Inverter Free Match 50HZ R410A Ceiling Floor Type 28 4 Dimension AMCF H09 4R1 AMCF H12 4R1 AMCF H18 4R1 ...
Страница 80: ...AUX DC Inverter Free Match 50HZ R410A Free Match outdoor unit 80 ...
Страница 106: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 106 Communication failure between indoor and outdoor unit ...
Страница 107: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 107 Outdoor protection phase sequence ...
Страница 108: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 108 Cooling high pressure protection ...
Страница 109: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 109 Heating high pressure protection ...
Страница 110: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 110 Cooling low pressure protection ...
Страница 111: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 111 Heating low pressure protection ...
Страница 112: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 112 Cooling exhaust temperature protection ...
Страница 113: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 113 Heating exhaust temperature protection ...
Страница 114: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 114 Refrigerant shortage or four way valve failure protection ...
Страница 115: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 115 Sensor failure protection ...
Страница 117: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 117 Poor effect ...
Страница 118: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 118 ...
Страница 119: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 119 Abnormal sound or viberation ...
Страница 120: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 120 ...
Страница 121: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 121 Abnormal odor ...
Страница 122: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 122 Air switch action when air conditioner starting up ...
Страница 123: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 123 Air conditioner water leakage ...
Страница 132: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 132 Wired controller XK 05 ...
Страница 133: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 133 ...
Страница 134: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 134 Installation of wired controller ...