AUX DC Inverter Free Match 50HZ R410ALow ESP Ducted type
47
7. Explode view
AMSD-H07/4R1,AMSD-H09/4R1,AMSD-H12/4R1
N0.
Material code
Part Name
Qty
Remark
1
16421028000132
Btm pan A
1
2
16320009000001
Drip tray asm
1
3
16421002000295
Bracket fan blower
1
4
16421028000133
Btm pan B
1
5
16421038000171
Cover elec Box
1
6
16330001000013
Asm control box
1
6.1
11222542000029
Main PCB
1
6.2
16427001000064
Terminal block
1
6.3
16422005000002
Transformer
1
6.4
11330010000052
Fan capacitor
1
6.5
16430007000003
Air sensor 15K3950 XH2 0.5m
1
6.6
16430007000007
Coil sensor 20K3950 XH2 0.5m
1
6.7
11220544000008
Wire clip
1
7
16420011000010
Knob
2
8
16421014000060
Plate valve
1
9
16421001000554
Plate right Side
1
10
16421040000042
Plate hanging
4
11
16440001000017
Drain pump
1
optional
12
16445034000012
Switch floating senor
1
optional
13
16421005000439
Plate top cover
1
14
16430001000510
Fan motor
1
15
16444002000016
Top blower housing
2
16
16444001000033
Fan blower
2
17
16444002000017
Btm blower housing
2
18
16421001000555
Plate left Side
1
19
16324009000169
Evap asm
1
Содержание AMCA-H09/4R1A
Страница 1: ...AUX DC Inverter Free Match 50HZ R410A 1 SERVICE MANUAL DC Inverter Free Match R410a ...
Страница 28: ...AUX DC Inverter Free Match 50HZ R410A Ceiling Floor Type 28 4 Dimension AMCF H09 4R1 AMCF H12 4R1 AMCF H18 4R1 ...
Страница 80: ...AUX DC Inverter Free Match 50HZ R410A Free Match outdoor unit 80 ...
Страница 106: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 106 Communication failure between indoor and outdoor unit ...
Страница 107: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 107 Outdoor protection phase sequence ...
Страница 108: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 108 Cooling high pressure protection ...
Страница 109: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 109 Heating high pressure protection ...
Страница 110: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 110 Cooling low pressure protection ...
Страница 111: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 111 Heating low pressure protection ...
Страница 112: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 112 Cooling exhaust temperature protection ...
Страница 113: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 113 Heating exhaust temperature protection ...
Страница 114: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 114 Refrigerant shortage or four way valve failure protection ...
Страница 115: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 115 Sensor failure protection ...
Страница 117: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 117 Poor effect ...
Страница 118: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 118 ...
Страница 119: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 119 Abnormal sound or viberation ...
Страница 120: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 120 ...
Страница 121: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 121 Abnormal odor ...
Страница 122: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 122 Air switch action when air conditioner starting up ...
Страница 123: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 123 Air conditioner water leakage ...
Страница 132: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 132 Wired controller XK 05 ...
Страница 133: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 133 ...
Страница 134: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 134 Installation of wired controller ...