AUX DC Inverter Free Match 50HZ R410A
Installation
95
8.5 Daily maintenance
Clean filter net
◇
Before cleaning the filter, ensure the unit is switched off and the power is off.
◇
Forbidden to use water clean the filter , it will hurt PCB or get an electric shock.
◇
When cleaning filter net, be sure to stand sreadily,andplease be carefulif using a lift or others.
Washing filter net
◇
Use vacuum or water to clean the net.
◇
In order to ensure the best performance of your air conditioner, clean the air filter regularly,We recommend
cleaning once a month or more frequently if required.
◇
When the filter is very dirty it can be washed in detergent and hot water (below 45
℃
).
◇
Ensure the filter is fully dry before reinstallation to avoid risk of electric shock or short circuiting.
◇
Do not dry the filter using direct sunlight.
Check at the beginning of each season
◇
Check whether there are no physical obstructions at the air inlet or outlet of either indoor or outdoor unit.
◇
Check whether there are garbage at the water outlet.
◇
Check whether electrical cables are in good condition, particularly the earth cable.
◇
When power on, check weather letters display on the screen of the wired controller.
◇
When working in winter,the system must be power on for 8 hours beforethe first time start up.
Check at the end of service season
◇
Operate for 2~3 hours under the ventilation condition; remove the moisture of the indoor unit..
◇
If not use air conditioner in a long time, please cut off the power to save energy, the letter will disappear on wired
controller.
◇
Take the batteries out of remote controller.
◇
Use dustproof to cover the
outdoor unit
.
8.6Sound level of different running status
Содержание AMCA-H09/4R1A
Страница 1: ...AUX DC Inverter Free Match 50HZ R410A 1 SERVICE MANUAL DC Inverter Free Match R410a ...
Страница 28: ...AUX DC Inverter Free Match 50HZ R410A Ceiling Floor Type 28 4 Dimension AMCF H09 4R1 AMCF H12 4R1 AMCF H18 4R1 ...
Страница 80: ...AUX DC Inverter Free Match 50HZ R410A Free Match outdoor unit 80 ...
Страница 106: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 106 Communication failure between indoor and outdoor unit ...
Страница 107: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 107 Outdoor protection phase sequence ...
Страница 108: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 108 Cooling high pressure protection ...
Страница 109: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 109 Heating high pressure protection ...
Страница 110: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 110 Cooling low pressure protection ...
Страница 111: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 111 Heating low pressure protection ...
Страница 112: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 112 Cooling exhaust temperature protection ...
Страница 113: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 113 Heating exhaust temperature protection ...
Страница 114: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 114 Refrigerant shortage or four way valve failure protection ...
Страница 115: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 115 Sensor failure protection ...
Страница 117: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 117 Poor effect ...
Страница 118: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 118 ...
Страница 119: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 119 Abnormal sound or viberation ...
Страница 120: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 120 ...
Страница 121: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 121 Abnormal odor ...
Страница 122: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 122 Air switch action when air conditioner starting up ...
Страница 123: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 123 Air conditioner water leakage ...
Страница 132: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 132 Wired controller XK 05 ...
Страница 133: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 133 ...
Страница 134: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 134 Installation of wired controller ...