Chapter 7:
Troubleshooting
Autoscope IntelliSight User Guide
©2022 Image Sensing Systems Inc.
7-5
Symptoms
The following describe symptoms that may occur during Supervisor operations.
Symptom:
Add device by IP does not work
Probable Cause:
There are several possibilities.
a) The wrong IP address was entered. The address must be of the WAN port
of the IntelliSight Processor.
b) The device is not connected to a routed network or is connected to a
network that uses port forwarding, which is not supported.
c) The device is not active.
Suggested Action:
Do the following.
1. Verify that the IP address is correct.
2. Verify that the device is connected to the routed network and that it is
active.
3. If the problem persists, contact Technical Support.
Symptom:
Cannot set output in Easy Setup
Probable Cause:
The Set Output action has not been activated for the condition.
Suggested Action:
In the Zones Explorer section, click the
+
to the right of the condition and select
Set Output
.