![Autoscope Image Sensing IntelliSight Скачать руководство пользователя страница 104](http://html1.mh-extra.com/html/autoscope/image-sensing-intellisight/image-sensing-intellisight_user-manual_3022789104.webp)
Chapter 7:
Troubleshooting
Autoscope IntelliSight User Guide
©2022 Image Sensing Systems Inc.
7-2
Message:
The following issue(s) was found in the detection configuration:
The current device setup is newer that this supervisor. Use Supervisor version
x.x to edit.
Description:
The current version of the Supervisor is not compatible with the detection
configuration for the device.
Suggested Action:
Use Supervisor version x.x to access the device.
Message:
The following issue(s) was found while restoring an archive:
Archive model ‘xxx’ does not match target model ‘yyy’. Please select an archive
with a model that matches the target model.
Description:
The archive file selected for the restore operation is for a different device type
(e.g., the selected file is for a IntelliSight Processor but the selected device is a
IntelliSight Camera).
Suggested Action:
Click
OK
, then select the correct archive file and retry the operation.
Message:
The following issue(s) was found in the detection configuration:
Failed to reserve Output xx on I/O Server yyy because Outputs were not found.
Go to Zone Setup page to reserve another output.
Description:
The indicated output could not be reserved for the camera. This is most likely
caused by the IntelliSight Processor not being connected to an I/O Module or the
I/O Module not operating correctly.
Suggested Action:
Click
OK
. If the camera is supposed to use I/O card outputs, verify that the
IntelliSight Processor is connected to an I/O Module and that the module is
operating correctly.
Message:
The following issue(s) was found in the detection configuration:
Failed to reserve xxx on I/O Server yyy because it is already reserved by another
device. Go to Zone Setup page to reserve another output.
Description:
The output xxx is already reserved on IntelliSight Processor yyy by another
IntelliSight Camera. If the conflict is not resolved, the camera will still do
detection; however, it will not be able to transmit any I/O state to the IntelliSight
Processor.
Suggested Action:
Click
OK
. Go to the Zone Setup screen in the Supervisor and select a different
output. If a new output is not selected, additional messages will appear
indicating that the setup is invalid.