Page - 41
Cooling
Problem
Unit is not generating chlorine.
Typical Solution
Internal temperature of unit has exceeded “Shutoff temp”, viewable in Setup Menu. Will turn off
chlorine generation for five (5) minutes or until temperature decreases. If this is not causing a
chlorine shortage, let the unit automatically cool and resume normal operation.
Move the Pool Pilot
®
to a shaded area if too hot.
Blank display
Problem
The Pool Pilot
®
display is blank.
Typical Solution
1. If the display is in bright sunlight, then shade the display to read.
2. Verify external time clock has not turned off power to the Pool Pilot
®
. (Temporarily override the time
clock, if desired, to check the Pool Pilot
®
.)
3. Verify local shut off switch and / or main circuit breaker for the Pool Pilot
®
is turned on.
4. If power is provided to unit by an external control device, verify power is provided to and from the
device.
5. Fuse may be blown. See "Fuse Location and Ratings" on page 11.
No Error Displays
Problem
Salt level on display does not match pool store or salt test strip.
Typical Solution
1. The test may have been faulty or the salt strips may be old or damaged. Have salt level rechecked at
local pool store.
2. If the discrepancy is more than 400 ppm (mg/L), calibrate salt. See "Calibrate Salt" on page 21.