Page - 30
Configuring the Power Supply for 110V-120V Operation:
1. Remove the cover by loosening the four recessed Phillips screws in the front corners of the cover.
2. Move the RED wire from the third terminal up to the second terminal
3. Move the YELLOW wire from the fourth terminal down to the fifth terminal.
4. Install the fuse labeled FUSE: 2A 250V 3AG SLO BLO into the fuse clip on the power supply board as
shown in the photo below.
*Note: If a 110V cord is needed, you can order the AutoPilot Power Cord Kit #STK0196. You
may also obtain a 16 AWG 2 conductor w / ground power cord, suitable for outdoor applications,
from your local hardware or electrical supply store.
110V - 120V Configuration
Figure 14
220V - 240V Configuration
Figure 15
8.7.b AC Input Voltage
WARNING - Failure to heed the following may result in permanent injury or death.
l
The Pool Pilot
®
control center supply circuit must be protected by a ground-fault circuit- interrupter
(GFCI).
CAUTION - Failure to heed the following may result in equipment damage.
l
The AC input cannot be provided by an ORP Controller.
The Pool Pilot
®
control center is typically provided input power either directly from a GFCI
breaker or from a timer or controller. Determine which is best for your application. Although not
required, ideally the circulation pump and Pool Pilot
®
are controlled by the same timer.
Connecting to an External Timer or Controller
1. Measure and cut ½” (13 mm) nonmetallic flexible conduit to reach from the power source to the Pool
Pilot
®
2. Feed the wires (not supplied) from Pool Pilot
®
through the conduit.
3. At time clock or external controller relay, connect AC power wiring to the load side or the same location
as the circulation pump wires (pump connected to circuit breaker, time clock or electronic controller).
4. Connect the ground wire to the ground of the power source.
Figure 16