SECTION 5 - FEATURES
l
Patented temperature compensation for chlorine output control.
l
Programmable microprocessor control.
l
Multi-language digital display (English, Spanish, French, German, Italian and Czech).
l
Digitally controlled power to the cell.
l
Tri-sensor circuitry to monitor water flow, water temperature, and salt level.
l
Calculates and displays amount of salt needed to reach the recommended 3,000 ppm (mg/L) salt
concentration level.
l
On board diagnostic and test programs.
l
Optional CoPilot
®
upgrade brings Ozone to the pool.
l
Can automatically reduce purifier output when pool cover is closed. (Optional 863A Expansion Board and
Cover Switch must be installed.)
l
Chlorine production (salt addition) can be delayed for up to 28 days.(Optional 863A Expansion Board)
5.1 Patented Temperature Compensation
WARNING - Failure to heed the following may result in permanent injury or death.
l
Pool or Spa water temperature should not exceed 104°F (40°C).
The water temperature sensor works in conjunction with the purifier % feature to automatically
adjust chlorine output based upon changes in water temperature. This feature operates between
55°F and 125°F (13°C - 52°C).
As water temperature falls below 65°F (18°C), the controller will automatically reduce the purifier
% and will reduce the maximum % that can be selected. This feature prevents the controller from
generating excessive chlorine in cold water where it is not needed and prevents premature cell
failure.
At 55°F (13°C) or colder water temperatures, the controller will adjust to a fixed 1% output, thus
preventing over-chlorination and premature cell failure.
5.2 Water Manifold Assemblies - Available Options
CAUTION - Failure to heed the following may result in equipment damage.
l
The Digital Nano manifold may only use the PPC1 cell. The Digital Nano+ may use either the PPC1 or
PPC2 cell.
The Digital Nano uses the automatic-flow bypass manifold assembly (models PPM1, PPM1M).
The Digital Nano should only use the PPC1 cell.
The Digital Nano+ uses the patented automatic-flow bypass manifold assembly (models PPM2,
PPM2M) with a PPC2 cell. The Digital Nano+ may also use a PPC1 cell, but the maximum
chlorine output will be lower. See "Specifications" on page 6.
The CoPilot
®
manifold assembly comes with an automatic-flow bypass, check valve assembly
and ozone injector venturi assembly.