Page - 29
8.6 Mounting the Chlorinator
ATTENTION: To ensure adequate cable length, we recommend plumbing the
manifold first and then mounting the control unit close enough so that the cables
will reach. The Tri-sensor and cell cables are 12’ (3.6 m) long. The selected
location should allow easy access for service and maintenance.
WARNING - Failure to heed the following may result in permanent injury or death.
l
All electrical connections should be made by a licensed electrician or certified electrical contractor.
l
Ensure electrical power is disconnected before wiring the unit. Follow all state / local NEC (CEC if
applicable) electrical codes. Use copper conductors, only.
The Pool Pilot
®
is suitable for indoor or outdoor mounting. When connected to 230 Vac, the Pool
Pilot
®
control unit must be installed at least 5’ (1.5 m) horizontal distance from the pool or spa
wall. When connected to 115 Vac, the Pool Pilot
®
control unit must be installed at least 10’ (3 m)
horizontal distance from the pool or spa wall. Greater distances may be required by local codes.
The Pool Pilot
®
control unit is designed to mount vertically on a flat surface with the wiring inputs
facing downward. The enclosure is designed to allow heat to dissipate from inside the box. It is
important the top or bottom of the enclosure is not blocked.
Do not mount the Pool Pilot
®
control unit inside a panel or a tightly enclosed area lacking proper
and full ventilation.
To avoid damage to wiring and connectors, read the following section before proceeding:
1. Hold the Pool Pilot
®
chassis level in the selected mounting location. Through the top, narrow portion of
the mounting slots, mark the wall for the four (4) mounting holes.
2. Plastic anchors and screws have been provided for concrete or stucco walls; anchors are not required
when mounting to wood or composite materials. Drill and install the plastic anchors (as applicable).
Tighten the screws into the anchors, temporarily leaving a ¼” (7.0 mm) gap between the wall and the
underside of the screw heads.
3. Holding the Pool Pilot
®
slotted openings to the screw heads, allow the screw heads to pass through the
larger portion of the mount holes. Hang the power center on the four (4) mounting screws. Tighten the
screws using a long shaft screwdriver.
8.7 Electrical Connections
8.7.a Electrical Connections Overview
CAUTION - Failure to heed the following may result in equipment damage.
l
Connecting 230 Vac to a unit that has been configured to 110-120 Vac will result in permanent damage
to the unit. Damage due to incorrect wiring is not covered under the warranty.
WARNING - Failure to heed the following may result in permanent injury or death.
l
All electrical connections should be made by a licensed electrician or certified electrical contractor.
A high voltage AC input provides power to the control center. Low voltage cables provide power
from the Digital Nano / Nano+ control center to the Tri-sensor and cell.
The AC input voltage of the Digital Nano / Nano+ has been preconfigured at the factory for
230V. This voltage configuration can be changed in the field by a qualified electrician, if
required.
Refer to the wiring diagram located on the inside of the power center cover to reconfigure the
wires on the terminal block if the unit AC input voltage is going to be changed from 230 Vac to
115 Vac, or see Figure 14 and Figure 15.