7.5 View Setup
A program and parameter menu used to view the currently programmed settings.
Press the MENU button, then press UP or DOWN arrow until “View Set Up” is displayed and
press the SELECT button. The display will automatically sequence through the following
displays and then return to normal operation. You can also press the UP or DOWN arrow to
scroll forwards and backwards. Press the MENU button again to skip the remaining displays and
exit back to normal operation. The following information is displayed:
l
“Nano” or “Nano+”
l
“Software V #” (The version number of Main Board software)
l
“Serial #” (The Digital Nano / Nano+ serial number)
l
“Display V #” (The version number of Display Board software)
l
“Expansion V#” (The version number of the Expansion Board software)
l
“Power level” (The amperage driven to the cell. Set by the factory to 5A)
l
“Audio alarm On / Off” (Set by the factory to Off)
l
“##, ### gallons (liters)” (The pool volume programmed in Installation Menu; 15,000 (60,000 liters) is the
factory setting)
l
“Reverse = # hrs.” (The reverse rate programmed in Installation Menu: 4 hrs. is factory setting)
l
“Temp. adjust = #” (The temperature adjustment variation of actual Tri-sensor reading)
l
“Salt #” (The salt calibration adjustment variation of actual Tri-sensor reading)
l
“Purifier” (The system mode selected. Purifier is the factory setting)
l
“Shutoff Temp” (Internal temperature of the unit at which it goes into a 5 minute cool-down period)
l
“Max temp” (Maximum internal temperature reached)
7.6 Review Of Installer, Owner, & Maintenance Menu Programming
Note: Once programmed for the installation site, the following menu items should not require
regular access. See "Basic Operational Programming" on page 19.
7.6.a Set Pool Volume
The pool volume must be programmed for the “Add salt ### lb (kg)” display to be accurate. See
"Calculating Pool Volume" on page 34.
1. Press MENU, press
△
or
▽
until “Installer menu” is displayed, then
press and hold SELECT for 13
seconds.
2. Press
△
or
▽
until “Set pool volume” is displayed, then press SELECT.
3. Factory setting is 15,000 gallons (60,000 Liters). The range is 500 to 125,000 gallons (2,000 to
500,000 Liters).
4. Press
△
or
▽
until correct pool size is displayed, then press SELECT.
5. Press
△
or
▽
until “End menu mode” is displayed, then press SELECT.
7.6.b Calibrate Salt
Note: The unit has been calibrated at the factory and should not require further adjustments. In
the event the salt display does not match on-site test results, follow these steps (it is necessary
to wait 2 minutes after water flow has started before calibrating salt):
1. Press MENU, press
△
or
▽
until “Maintenance Menu” is displayed, then press SELECT.
2. Press
△
or
▽
until “Calibrate salt” is displayed, then press SELECT.
3. Press
△
or
▽
until the number on the display matches the accurately measured pool sample, then
press SELECT. The maximum adjustment is ± 1,000 ppm (mg/L).