Page - 19
7.3 Basic Operational Programming
7.3.a Adjusting the Purifier Output %
Typically, once the initial setting is established, very little adjustment is needed. The Purifier
Output % setting refers to the amount of time the cell is energized within a 15 minute cycle. The
system cycles on-and-off, as indicated on the display's lower right display and “On,” when
generating chlorine. Higher settings will generate more chlorine.
1. Press the UP / DOWN arrow buttons to enter the purifier adjustment mode.
2. Use the UP / DOWN arrow buttons to adjust the purifier / chlorine output percentage to the desired
output: from 0% (off) to 100 % ; then press SELECT to save the new output value and default back to
the normal display. At start up of a new system, the standard output setting starting point is 50%.
50% setting = 50% of 15 minutes or 7.5 minutes ON and 7.5 minutes OFF.
25% setting = 3.75 min ON, 11.25 min OFF
Once the percentage is set, the unit will implement the temperature compensation algorithm
based on current water temperature.
7.3.b Boost or Super Boost
The Boost feature is used to increase the purifier % from its normal setting to 100% for a
cumulative 24 hour or 72 hour period. When the Boost period expires or is manually terminated,
the purifier % returns to its previous setting and normal operation.
l
Boost purifier output to 100% for 24 hours: From the normal operation mode, press and release the
BOOST button. The display will flash: "Boost 24 hour on", then “Boost hh” (with the “hh” actually being the
displayed hours remaining in the boost period).
l
Boost purifier output to 100% for 72 hours: From normal operation mode, press and hold the BOOST
button until: “Boost 72 hour on” is displayed; then release the BOOST button. Display will show: “Boost”
for approximately 8 seconds, after that: “Boost 72 hour on” will display; then, “Boost hh” (with the “hh”
actually being the displayed hours remaining in Boost period).
l
If an external time clock or controller turns off power to the Pool Pilot
®
while Boost is active, the Boost
timer is stored in memory and the Boost time countdown will resume when power is reapplied to the unit.
l
If water flow is stopped during a Boost cycle, chlorine generation will stop while there is no flow but the
Boost timer will continue to count down as long as the Pool Pilot
®
has power.
Caution: Regardless of retractable pool cover position, when the Boost feature is activated the
unit will increase chlorine production to 100% for 24 or 72 hours based on the Boost time
selected.
To exit Boost or Super Boost mode and revert to normal operation:
l
Allow the Boost cycle to expire, or
l
Press BOOST at any time to manually deactivate Boost.
7.3.c Purifier Mode
The Pool Pilot
®
will automatically display informative messages about the condition of the unit
(purifier output %, water temperature, warning messages, etc.), and responds to manual
adjustment of purifier % setting (as described below). The unit will revert to the normal display if
there is no activity on the keypad for thirteen (13) or more seconds.