C) Over run
C) Over run
C) Over run
C) Over run
(1) Checking timing :
When receiving data from host computer at ‘Ready’ position.
(RS232C connection)
(2) How to check :
By detecting problem during internal processing.
(3) Cause of the error :
The new data is input before completing the process of current data.
(4) How to recover :
LCD
How to recover
Beep
sound
ERROR LED
status
Upper Lower
Error detection
ON
ON
E53
Over run
Press any button down.
OFF
ON
E53
Over run
Reset by power switch.
(OFF / ON)
OFF OFF READY
Set communication condition
again by front panel.
OFF OFF READY
Power switch on again
OFF
OFF
READY
Note : The data will be lost after turn off the power switch.
D) Buffer Full
D) Buffer Full
D) Buffer Full
D) Buffer Full
(1) Check timing :
When receiving data from host computer at ‘Ready’ position.
(2) How to check :
By receiving new data when receiving buffer is full.
(3) Cause of the error :
By receiving new data when receiving buffer is full.
(4) How to recover :
LCD
How to recover
Beep
sound
ERROR LED
status
Upper Lower
Error detection
ON
ON
E54
Buffer Full
Press any button down.
OFF
ON
E54
Buffer Full
Power switch on again
OFF OFF READY
a) The error occurs when sending data exceeds 256 byte.
b) Please check communication condition and cables.
c) The error occurs when remaining memory become 256 byte in
X ON / X OFF mode.
d) Reset by power switch to recover.