background image

46

15

VDROP ERROR MESSAGES

ERROR:

LARGE LEADS

NOT CONNECTED

'Y' TO CONTINUE

ERROR:

BAD CONNECTION

ON LARGE LEADS

'Y' TO CONTINUE

ERROR:

SMALL LEADS

REVERSED

'Y' TO CONTINUE

ERROR:

SMALL LEADS

NOT CONNECTED

'Y' TO CONTINUE

ERROR:

CHECK LARGE

RED LEAD

'Y' TO CONTINUE

ERROR:

CHECK LARGE

BLACK LEAD

'Y' TO CONTINUE

One of the following may appear during any drop test sequence. Correct 

the situation before continuing.

CHARGING CABLE VDROP™ (Cont.)

One or both of the large leads are not 

connected. 

Tester detected that one of the 

large leads does not have a good 

connection.

Tester detected that the large black 

lead is not connected properly

Tester detected that the large red 

lead is not connected properly

Note: On the large leads, both 

sides of the jaws must make a 

good connection

One or both of the small external 

leads is not connected

The tester detected that the small 

leads are hooked up backwards 

the tester should also beep when 

it occurs

BATTERY

Low

Current

Jaw

High

Current

Jaw

MAINTENENCE

IMPORTANT: 

Both jaws of each 

clamp must firmly engage all 

terminals. The copper jaw contains 

the smaller gauge wire that reads 

the voltage and the silver jaw 

contains the larger conducting 

wire that draws the load in each 

test. Jaw insulation is necessary 

for accurate readings. Damaged 

clamps or loose wires will affect the 

readings. Keep clamps clean and 

in good repair. 

DO NOT ATTEMPT 

TO REPLACE CLAMPS WITH 

ANYTHING OTHER THAN AUTO 

METER CLAMPS.

CHECK OFTEN FOR LOOSE JAWS 

OR DAMAGED INTERNAL PLASTIC 

SHOULDER INSULATORS

BATTERY CLAMP REPLACEMENT

Over time the battery clamps will need to be replaced if the following are 

indicated:

CCA values seem to be way off.  

If there is continuity between the silver and copper jaw.  

If there is excessive damage or corrosion to the cables or clamps.

PROCEDURE

n  

Disconnect the back cover. 

Remove the battery to prevent shorting. 

Disconnect the two small wires from the PC board.  

Remove the large cables from the copper busses.    

Carefully pull each wire through the grommets.  

Reverse the procedure in replacing new clamps.  

 

Caution:  

Make sure the red clamp wires are attached to the 

positive buss and the black clamp is attached to the negative 

buss.  Putting a little mineral spirits on the new cable ends will 

increase ease of insertion through the grommets. 

BATTERY REPLACEMENT

When the LCD indicates a low internal battery. Remove the back cover 

and replace the battery with a 9 volt Alkaline battery.

CLAMP INSPECTION

Содержание Remy BCT-200J

Страница 1: ...res the voltage drop of the starting and charging circuit The BCT 200J is automated and menu driven with simple hook up methods for testing the negative and positive legs in one operation Special test...

Страница 2: ...ble Optional PR 15 Infrared printer Optional AC24J carrying case Optional AC 10 PC Interface adapter cord Optional AC 27 Alternator Adapters Optional AC 35 PC download program Weight 4 27 lbs What to...

Страница 3: ...9 Single Split 7 Magnetic Circuit VDrop Test 30 32 Without IMS With IMS 8 Key Circuit VDrop Test 33 36 Without OCP With OCP 9 Liftgate VDrop Tests 37 39 10 Alternator Bench Test 40 45 Maintenance 46 C...

Страница 4: ...gulator setting can cause lead sulfate to gradually build up and crystallize on the plates greatly reducing the battery s capacity and ability to be recharged n Cycling Excessive drain on battery when...

Страница 5: ...and alternator for loose connections loose mounts and frayed or cracked wires Loose Hold downs Corrosion Check for loose belts and auto tensioner Gives the version of the software NOTE This screen is...

Страница 6: ...software applications consult your software manual n Under Column Date Format select General then Finish n After the file is loaded you can delete unwanted rows and format columns as desired The follo...

Страница 7: ...hop for a PM Service NOT when the vehicle is having electrical system issues For a vehicle with a suspected electrical problem use the individual tests starting with the batteries then the cables and...

Страница 8: ...nections before testing the batteries If the batteries or posts are damaged replace the batteries Make sure the batteries are free from dirt cracks and leaks and that the connections are clean and sec...

Страница 9: ...llow the batteries to stabilize for at least 10 minutes after being charged or loaded before running a test 1 Scroll down the main menu to DOWNLOAD Press Y Enter to select Using Auto Meter s optional...

Страница 10: ...the reason for battery bank failure Clean posts and connections are essential when checking each battery Make sure batteries not being tested are disconnected INSPECT BATTERY FOR DIRT LEAKS OR CRACKS...

Страница 11: ...e SETUP From the main menu select SETUP Select the temperature in Fahrenheit or Centigrade If answered YES the above screen will appear at the beginning of the first test for a vehicle Each digit with...

Страница 12: ...f ERROR appears the connections has not been established VOLT METER Select VOLT METER from the main menu and press Y Enter This gives the user a chance to check the voltage from the large clamps and t...

Страница 13: ...00J Press Print You should be within 15 ft of the printer Wait for the screen to clear before moving the BCT 200J It takes a moment to send all the test data The BCT 200J also operates the AC 14 print...

Страница 14: ...is a single or dual system Single has one cable from the alternator output terminal Dual system has two cables attached to the output terminal Every load that the tractor and trailer utilize must be...

Страница 15: ...he silver jaw contains the larger conducting wire that draws the load in each test Jaw insulation is necessary for accurate readings Damaged clamps or loose wires will affect the readings Keep clamps...

Страница 16: ...ck to ground case output adapters recommended CONNECT LARGE LEADS TO THE ALTERNATOR Y TO CONTINUE Check the alternator tag or housing and use the key to select the rated output See picture below ALTER...

Страница 17: ...ition key to the run position Non Remote Sense empty port Non Remote Sense Alternator ALTERNATOR BENCH TESTING Cont TURN MOTOR SWITCH OFF Y TO CONTINUE TURN BATTERY SWITCH OFF N TO CANCEL TURN BENCH P...

Страница 18: ...battery is too weak or if the cables or leads of the bench have too high of a voltage drop then the battery and or cables will need to be serviced before continuing with the alternator test If the ben...

Страница 19: ...d is producing high ripple ALTERNATOR BENCH TESTING Cont ALTERNATOR AND TESTER SHOULD BE HOOKED UP Y TO CONTINUE DOES ALTERNATOR HAVE A REMOTE SENSE N OR Y CONNECT REMOTE SENSE POST TO OUTPUT POST Y T...

Страница 20: ...key to select the rated output See picture below ALTERNATOR BENCH TESTING Cont MAKE SURE THAT THE BELT IS STRAIGHT Y TO SCROLL TIGHTEN THE BELT Y TO SCROLL ATTACH BLACK BENCH LEAD TO GROUND ADAPTER Y...

Страница 21: ...t Bench Test and press Y Enter PRESS Y TO SCROLL THROUGH BENCH SETUP OR TO SKIP Press Y to scroll through the prompts for connecting the alternator to the bench or press the Up key to skip over the pr...

Страница 22: ...at the entered current Reports the drops at the entered current 24 Volt 12 Volt 24 Volt 12 Volt 24 Volt 12 Volt 24 Volt Main Starting Cables Magnetic Circuit Straight Drive Maximum drop at 300 Amps is...

Страница 23: ...S N TO CANCEL Wait for test to complete its testing cycle LIFTGATE VDROP TESTS Cont Then connect small leads to the battery or along the circuit being tested as illustrated in the setup and press Y E...

Страница 24: ...st can be used to test the liftgate charging and motor circuits as well as any other circuit that includes a battery and cables and is designed to operate a load of 20 amps or more Select TRAILER CHAR...

Страница 25: ...e conditions of the cables Both the positive and negative circuit results will be indicated from the single test If the test does not pass correct the connection or replace the cable and run the test...

Страница 26: ...T GROUND KEY SWITCH VDROP TEST Cont OCP A will always be the small black lead A to B tests power at key switch A to C tests power out of keyswitch A to D tests power at the push button A to E tests po...

Страница 27: ...able and run the test again The BCT 200J will automatically resume the test after it is disconnected Just answer Yes when prompted 6 GENERIC VDROP VOLTAGE DROPS AT 250 AMPS 35 POS 29 NEG This example...

Страница 28: ...SCONNECT GROUND 8 KEY SWITCH VDROP TEST Note This is a real time test and the operator must observe and record the data when the key switch is energized S terminal wire must be removed from the soleno...

Страница 29: ...he test after it is disconnected Just answer Yes when prompted 6 GENERIC VDROP VOLTAGE DROPS AT 250 AMPS 18 POS 41 NEG This example is out of spec with a total drop of 59V MAGNETIC CIRCUIT TEST Cont M...

Страница 30: ...E CONNECTED TO ANY GROUND ON 24 VOLT SYSTEMS THIS LEAD MUST BE CONNECTED TO THE STARTER GROUND CHARGING CABLES STR MAIN CABLES MAG CIRCUIT LIFTGATE VDROP Connect the large red clamp to the disconnecte...

Отзывы: