14
47
The Charging System Test
performs this individual VDrop
Test before allowing you to test
the alternator’s output.
If all connections are correct press
(Y Enter) to begin VDrop Test. Wait
for a load to be applied.
LOADING
PLEASE WAIT...
The results will vary depending upon the conditions of the cables. Both the
positive and negative circuit results will be indicated. If the test does not pass,
correct the connection or replace the cable and run the test again. The BCT-200J
will automatically resume the test after it is disconnected. Just answer ‘YES’ when
prompted.
CHARGING CABLE VDROP™ (Cont.)
#7 CHRG CABLES
PASSED @ 130A
GOOD TO 192A
0.15POS 0.19NEG
#8 CHRG CABLES
OUT OF SPEC @
135A GOOD TO 123A
0.16POS 0.46NEG.
Determining if the charging circuit is a “single” or “dual” system
Single has one cable
from the alternator
output terminal.
Dual system has two
cables attached to the
output terminal. Every
load that the tractor
and trailer utilize must
be subtracted from the
amount of current that
can go to the batteries.
To vehicle loads
REVIEW TESTS
#30 12V BATTERY
GOOD BATTERY
12.55V CHRG 85%
EST. CCA 810
From the main menu select
REVIEW/PRINT
The last test will be displayed.
Press (+Up) or (-Down) key to
select the desired test. Press
OPTIONAL INFRARED PRINTER
The optional PR-15 printer receives an infrared beam from the BCT-200J
up to 40 ft. No connection cords are needed. For more instructions on
how to operate the printer consult the printer manual.
Printer Type --------------------------Thermal
Print Speed ------24-char. line per second
Paper------2.25 in x 80 ft. roll (included)*
Power ----------------------------- AC Adapter
Note:
Thermal Paper can be purchased at any office supply.
(N Esc.) to select MAIN MENU.
VDROP MENU
ALTERNATOR
STARTER TEST
>REVIEW/PRINT