52
9
BATTERY BANK (Cont.)
>CONNECT LARGE
LEADS TO THE
BATTERY BANK
'Y' TO CONTINUE
>BANK MUST BE
STABILIZED FOR
VALID RESULTS
'Y' TO CONTINUE
You will be instructed to connect
the large leads. Connect the red
clamp to the main positive cable
coming to the bank and the black
clamp to the main negative cable
leaving the bank.
Using the (+) or (-) key adjust the
temperature in units of 10 degrees.
This should be the temperature of the
battery(S). Consider where the vehicle
has been before adjusting.
Use the (+) or (-) key to select the
battery type, either AGM or regular
lead-acid.
Using the (+) or (-) key adjust the CCA
of an individual battery. If each battery
varies in CCA approximate an average. If
the CCA is unknown consider that most
truck batteries range from 625-950 CCA.
Press (Y Enter) to begin the test
and wait for results. Example is
at the top of page 10 (Individual
Battery Test).
Black Clamp at Negative Main
Red Clamp at Positive Main
>ENTER BATTERY
TEMP. 70F.
12.39V
'Y' TO CONTINE
>ENTER BATT TYPE
AGM USE +/-
12.39V
'Y' TO CONTINE
>ENTER SINGLE
CCA 650
12.39V
'Y' TO BEGIN
TESTING BANK
PLEASE WAIT...
Battery Bank of 3 Batteries
Connect large alligator clips as far
apart as possible.
For the most accurate and
repeatable tests always allow the
batteries to stabilize for at least
10 minutes after being charged or
loaded before running a test.
1.
Scroll down the main menu to DOWNLOAD. Press (Y Enter) to
select.
Using Auto Meter’s optional
adapter cord AC-10 insert the
plug into the jack on the BCT-
200J (see page 6) and then plug
the serial adapter into a free
serial port on your computer.
Note:
Most computers are configured with at least one serial port (identified
as COM 1), and some have a second serial port, usually identified
as (COM 2). Check your computer manual to locate and identify a serial
port connector. Even if you have a physical COM port you need to make
sure it is working properly before you proceed. Consult your computer
manual. If your computer serial port is configured for 25 pin you will need
to obtain an adapter from your computer store. If your computer does
not have an available serial port and you’re planning on using
Windows
HYPER Terminal
as illustrated below, you will need to buy and install an
adapter card with a serial port.
VOLT METER
J1708 DATA
SETUP
>DOWNLOAD
CONNECT ANALYZER
TO A P.C.
9600, N, 8, 1.
'N' TO CANCEL.
PC INTERFACE
2.
Using Auto Meter’s AC-35 Application Program
By purchasing Auto Meter’s PC Application Program, information
that is stored and collected in the BCT 200J can be easily
downloaded into a PC program format for storage. The AC-35
comes with a PC cable, installation and user instructions.