INDIVIDUAL BATTERY TEST

When the test results appear as 

GOOD BATTERIES after running 

the PM Check or Battery Bank 

Test there is no need to run the 

individual battery tests. Press (N 

Esc.) to return to the menu

Connect the large red clamp to the 

positive and the large black to the 

negative battery terminal. If the 

clamps are connected improperly 

you will be prompted to correct 

the problem. The tester will then 

revert back to the beginning or 

main menu. Be sure to use post 

adapters on threaded steel posts 

as illustrated on the next page 

then press (Y Enter).

If the battery bank test results are 

low you will be instructed to test 

each battery separately. Press (Y 

Enter) to continue.

Select BATTERY TEST from the 

main menu. 

Note!

  When testing batteries individually each battery should be 

disconnected. Avoid improper results and damage to the posts by using 

the included post adapters on threaded post batteries.

Always check for dirt and cracks or 

leaks in the battery.

Poor connections may be the 

reason for battery bank failure. 

Clean posts and connections are 

essential when checking each 

battery. Make sure batteries not 

being tested are disconnected.

>INSPECT BATTERY

 FOR DIRT, LEAKS

 OR CRACKS

 'Y' TO CONTINUE

>INSPECT POSTS

 AND CONNECTIONS

 'Y' TO CONTINUE

#211 12V BANK

GOOD BATTERIES

12.70V CHRG 100%

11.50V LOADED

#211 12V BANK

TEST SEPARATELY

12.38V CHRG 66%

 PM TEST

>BATTERY TEST

 BATTERY BANK

 VDROP TEST

IMPORTANT

Select the month as 01 to 12

Select the day as 01 to 31

Select the year as  04 to 99

Select the hour as 01 to 12 AM/PM

Select the minute as 01 to 60

If you select Yes you can change 

the MONTH, DAY, YEAR, HOUR 

and MINUTE.

To require a battery serial number before 

each battery test select YES. If YES is 

selected then before each battery test 

the tester will prompt for a 14 digit alpha-

numeric serial number. This serial number 

will be printed near the bottom of the 

printout along with the warranty code.

Can delete all test data or one item 

at a time.

>SET MONTH:01 

 USE +/-.

 'Y' TO CONTINUE

>SET DAY:02 

 USE +/-.

 'Y' TO CONTINUE

>SET YEAR:03 

 USE +/-.

 'Y' TO CONTINUE

>SET HOUR:10 AM

 USE +/-.

 'Y' TO CONTINUE

>SET MINUTE:12

 USE +/-.

 'Y' TO CONTINUE

>CHANGE THE TIME

01/31/03 10:12AM

  'N' OR 'Y'

>REQUIRE BATTERY

 SERIAL #? NO

 USE +/-.

 'Y' TO SELECT.

>DELETE STORED

 DATA

 USE +/-. 

 'N' OR 'Y'

SETUP (Cont.)

Содержание Remy BCT-200J

Страница 1: ...res the voltage drop of the starting and charging circuit The BCT 200J is automated and menu driven with simple hook up methods for testing the negative and positive legs in one operation Special test...

Страница 2: ...ble Optional PR 15 Infrared printer Optional AC24J carrying case Optional AC 10 PC Interface adapter cord Optional AC 27 Alternator Adapters Optional AC 35 PC download program Weight 4 27 lbs What to...

Страница 3: ...9 Single Split 7 Magnetic Circuit VDrop Test 30 32 Without IMS With IMS 8 Key Circuit VDrop Test 33 36 Without OCP With OCP 9 Liftgate VDrop Tests 37 39 10 Alternator Bench Test 40 45 Maintenance 46 C...

Страница 4: ...gulator setting can cause lead sulfate to gradually build up and crystallize on the plates greatly reducing the battery s capacity and ability to be recharged n Cycling Excessive drain on battery when...

Страница 5: ...and alternator for loose connections loose mounts and frayed or cracked wires Loose Hold downs Corrosion Check for loose belts and auto tensioner Gives the version of the software NOTE This screen is...

Страница 6: ...software applications consult your software manual n Under Column Date Format select General then Finish n After the file is loaded you can delete unwanted rows and format columns as desired The follo...

Страница 7: ...hop for a PM Service NOT when the vehicle is having electrical system issues For a vehicle with a suspected electrical problem use the individual tests starting with the batteries then the cables and...

Страница 8: ...nections before testing the batteries If the batteries or posts are damaged replace the batteries Make sure the batteries are free from dirt cracks and leaks and that the connections are clean and sec...

Страница 9: ...llow the batteries to stabilize for at least 10 minutes after being charged or loaded before running a test 1 Scroll down the main menu to DOWNLOAD Press Y Enter to select Using Auto Meter s optional...

Страница 10: ...the reason for battery bank failure Clean posts and connections are essential when checking each battery Make sure batteries not being tested are disconnected INSPECT BATTERY FOR DIRT LEAKS OR CRACKS...

Страница 11: ...e SETUP From the main menu select SETUP Select the temperature in Fahrenheit or Centigrade If answered YES the above screen will appear at the beginning of the first test for a vehicle Each digit with...

Страница 12: ...f ERROR appears the connections has not been established VOLT METER Select VOLT METER from the main menu and press Y Enter This gives the user a chance to check the voltage from the large clamps and t...

Страница 13: ...00J Press Print You should be within 15 ft of the printer Wait for the screen to clear before moving the BCT 200J It takes a moment to send all the test data The BCT 200J also operates the AC 14 print...

Страница 14: ...is a single or dual system Single has one cable from the alternator output terminal Dual system has two cables attached to the output terminal Every load that the tractor and trailer utilize must be...

Страница 15: ...he silver jaw contains the larger conducting wire that draws the load in each test Jaw insulation is necessary for accurate readings Damaged clamps or loose wires will affect the readings Keep clamps...

Страница 16: ...ck to ground case output adapters recommended CONNECT LARGE LEADS TO THE ALTERNATOR Y TO CONTINUE Check the alternator tag or housing and use the key to select the rated output See picture below ALTER...

Страница 17: ...ition key to the run position Non Remote Sense empty port Non Remote Sense Alternator ALTERNATOR BENCH TESTING Cont TURN MOTOR SWITCH OFF Y TO CONTINUE TURN BATTERY SWITCH OFF N TO CANCEL TURN BENCH P...

Страница 18: ...battery is too weak or if the cables or leads of the bench have too high of a voltage drop then the battery and or cables will need to be serviced before continuing with the alternator test If the ben...

Страница 19: ...d is producing high ripple ALTERNATOR BENCH TESTING Cont ALTERNATOR AND TESTER SHOULD BE HOOKED UP Y TO CONTINUE DOES ALTERNATOR HAVE A REMOTE SENSE N OR Y CONNECT REMOTE SENSE POST TO OUTPUT POST Y T...

Страница 20: ...key to select the rated output See picture below ALTERNATOR BENCH TESTING Cont MAKE SURE THAT THE BELT IS STRAIGHT Y TO SCROLL TIGHTEN THE BELT Y TO SCROLL ATTACH BLACK BENCH LEAD TO GROUND ADAPTER Y...

Страница 21: ...t Bench Test and press Y Enter PRESS Y TO SCROLL THROUGH BENCH SETUP OR TO SKIP Press Y to scroll through the prompts for connecting the alternator to the bench or press the Up key to skip over the pr...

Страница 22: ...at the entered current Reports the drops at the entered current 24 Volt 12 Volt 24 Volt 12 Volt 24 Volt 12 Volt 24 Volt Main Starting Cables Magnetic Circuit Straight Drive Maximum drop at 300 Amps is...

Страница 23: ...S N TO CANCEL Wait for test to complete its testing cycle LIFTGATE VDROP TESTS Cont Then connect small leads to the battery or along the circuit being tested as illustrated in the setup and press Y E...

Страница 24: ...st can be used to test the liftgate charging and motor circuits as well as any other circuit that includes a battery and cables and is designed to operate a load of 20 amps or more Select TRAILER CHAR...

Страница 25: ...e conditions of the cables Both the positive and negative circuit results will be indicated from the single test If the test does not pass correct the connection or replace the cable and run the test...

Страница 26: ...T GROUND KEY SWITCH VDROP TEST Cont OCP A will always be the small black lead A to B tests power at key switch A to C tests power out of keyswitch A to D tests power at the push button A to E tests po...

Страница 27: ...able and run the test again The BCT 200J will automatically resume the test after it is disconnected Just answer Yes when prompted 6 GENERIC VDROP VOLTAGE DROPS AT 250 AMPS 35 POS 29 NEG This example...

Страница 28: ...SCONNECT GROUND 8 KEY SWITCH VDROP TEST Note This is a real time test and the operator must observe and record the data when the key switch is energized S terminal wire must be removed from the soleno...

Страница 29: ...he test after it is disconnected Just answer Yes when prompted 6 GENERIC VDROP VOLTAGE DROPS AT 250 AMPS 18 POS 41 NEG This example is out of spec with a total drop of 59V MAGNETIC CIRCUIT TEST Cont M...

Страница 30: ...E CONNECTED TO ANY GROUND ON 24 VOLT SYSTEMS THIS LEAD MUST BE CONNECTED TO THE STARTER GROUND CHARGING CABLES STR MAIN CABLES MAG CIRCUIT LIFTGATE VDROP Connect the large red clamp to the disconnecte...

Отзывы: