36
25
Connect large leads to the
Starter
Then connect small leads to the
battery bank – the red on the
positive main and the black on
the negative main and not to an
individual battery. The added
small external leads will check
the main cables. Press (Y Enter).
>CONNECT SMALL
LEADS TO THE
BATTERY
'Y' TO BEGIN
>CONNECT LARGE
LEADS TO THE
STARTER
'Y' TO CONTINUE
Red
Starter
Positive
Black
Starter
Ground
STARTING VDROP™ MAIN CABLE. . . SINGLE
Just as the System Test checks the Magnetic Circuit first it also checks
the main starting cables.
If all connections are correct, wait
for a load test to be performed.
The results will vary depending upon and the conditions of the cables. Both the
positive and negative circuit results will be indicated from the single test. If the test
does not pass, correct the connection or replace the cable and run the test again.
The BCT-200J will automatically resume the test after it is disconnected. Just answer
‘Yes” when prompted.
Black Clamp at
Negative Main
Red Clamp at
Positive Main
BATTERY
HOOKUP
LOADING
PLEASE WAIT...
A= will always be the battery ground
A to B tests power at key switch
A to C tests po wer out of keyswitch
A to D tests power at the push button
A to E tests power out of the push button
A to F tests ground at the mag switch
A to G tests power at mag switch
NON OCP
Example: Connect small
black lead at A and small
red lead on B
KEY SWITCH VDROP™ TEST (Cont.) (NON OCP)
Note: D & E tests only pertain to
vehicles equipped with push button
start