background image

6

LKS 

- S2 24V DC

Danger spots by crush and shear points

Side-hung

Bottom-hung 

Roof windows / skyskylight domes

Louvre windows

              Danger spots: crush and shear points according to DIN EN 60335-2-103              

n

ote

n

ote

!

w

aRning

!

w

aRning

!

All devices must be permanently protected 
from dirt and moisture, if the drive is not
explicitly suitable for use in wet areas (see 
technical data).

Area of application

The drive shall only be used according to its intended use. 
For additional applications consult the manufacturer or his 
authorized dealer.

Mounting material

The required mounting material must to fi t with the drive 
and occurring load and, if necessary, supplemented.

Installation

These instructions address expert and safety-conscious 
electricians and / or qualifi ed personnel knowledgeable in 
electrical and mechanical drive installation.

Always check whether the system complies with current 
regulations. Special attention must be paid to the opening 
width, the opening area, the opening time and the opening 
speed of the window, the temperature range of the drives / 
external devices and cables as well as the cross section of 
the connecting cables as function of the cable length and 
power consumption.

All specifi cations for installation must be checked indepen-
dently and, if necessary, adjusted at the installation site. 
The connection assignment, the electrical supply data (see 
product lable) and performance limits (see technical data) 
as well as the mounting and installation instructions of the 
drive must be strictly observed and adhered to!

Do not reach into the window rabbet or the operating 
element (chain or spindle) during installation and opera-
tion! Ensure that, based on the installation position and 
the opening movement of the casement, persons cannot 
be trapped between the driven part of the window and
surrounding fi xed components (e.g. wall).

S

afety

 

inStRuCtionS

It is important to follow these instruc-
tions for the safety of persons. These
instructions shall be kept in a safe place 
for the entire service life of the products.

Risk of crushing and entrapment! 
Window can close automatically!

The integrated load cut-off stops the
drive during closing and opening when 
the drive is overloaded. 

The compressive force is absolutely 
suffi cient to crush fi ngers in case of 
carelessness.

Do not misuse the drive for other lifting
operations! 
Do not allow children to play with
this drive or its electric controls, including 
the remote control!

The safe operation, avoidance of injury to 
persons and damage to property, as well 
as risks, is only guaranteed by proper
installation and setting according to
these installation instructions.

Before installing the drive, check whether 
the casement is in good mechanical con-
dition, the weight in balance and whether 
it opens and closes easily!

Never connect 24 V DC drives to 230 V AC 
mains voltage! 

Danger to life!

s

afety

 i

nstruCtions

01

Содержание LKS S2 24V DC

Страница 1: ...according to Machinery Directive 2006 42 EC annex VI LKS S2 24V DC Rack and Pinion Drives for windows Assembly and Commissioning Instructions...

Страница 2: ...a Assembly drive with frame bracket K29 Installation step 4b Assembly drive with adjustable clamping B7 and frame bracket K82 Installation step 4c Assembly drive with adjustable clamping B7 and frame...

Страница 3: ...ng Caution Warning Danger due to electric current Caution Warning Risk of crushing and entrapment during device operati on is provided as a sticker with the drive Attention Warning Risk of damage to d...

Страница 4: ...s NSHEV natural smoke and heat exhaust ventilator s in accordance with EN12101 2 without dual purpose for ventilation The need for a risk assessment at the installation site due to the reasonably fore...

Страница 5: ...witch strips or Motor current monitoring systems internal and external Hold to run switch stops movement at HSK 20 mm at a closing force of 150 N at HSK 20 ZAA 5 Operating element in direct range of v...

Страница 6: ...e electrical supply data see product lable and performance limits see technical data as well as the mounting and installation instructions of the drive must be strictly observed and adhered to Do not...

Страница 7: ...able cable lengths and cross sections shall be selected in accordance with the manufacturer s technical data If necessary the cable types shall be coordinated with the competent local authorities and...

Страница 8: ...e instructed in all important opera ting steps If necessary he must be advised of all remaining risks dangers The end user shall be specifically instructed that no additional forces except pushing and...

Страница 9: ...e and heat exhausting systems SHEV as single drive Internal load dependend cut off switch S2 Options Drillings for front suspension Monitored motion run of 2 drives up to s 300 mm via USKM Order data...

Страница 10: ...formation on the most import ant caracteristics such as manufacturer s address article reference number and name technical caracteristics date of manufacturing with firmware version serial number cert...

Страница 11: ...2200 2400 2600 Abstand Antrieb Band ffnungswinkel 2 1 3 4 5 6 7 8 9 10 1 Hubl nge 100 mm 2 Hubl nge 200 mm 3 Hubl nge 300 mm 4 Hubl nge 400 mm 5 Hubl nge 500 mm 6 Hubl nge 600 mm 7 Hubl nge 700 mm 8...

Страница 12: ...balance The test procedure of drives may only be performed on a non slip and secured mat or a test fixture During the test run the test element must not be interfered with The test my only be conducte...

Страница 13: ...2 FAB 1 2 FAB 1 4 FAB 1 4 FAB Tools required Marker Grains Hammer Screwdriver slotted head cross or Torx size by site conditions Hexagonal wrench size 4 5 Fork wrench for SW13 SW14 Torque wrench Power...

Страница 14: ...et K82 for swivelling suspension Frame bracket K5 for swivelling suspension Adjustable clamping B7 Mounting with K5 or K82 Frame bracket K21K For moving the mounting level from the horizontal to the v...

Страница 15: ...g casement outwards opening Frame assembly HSK View on aluminium window View on PVC window Roof window outwards opening Frame assembly HSK Roof window outwards opening Frame assembly HSK View on alumi...

Страница 16: ...associated bolt 6 of the casement brackets F1 into the eyebolt of LKS Optionally adjust the pressure ball of the casement bracket F1 with grub screw and the spring Adjust casement pressure using of th...

Страница 17: ...linder head screws M6 of the adjustable clamping B7 Slide the adjustable clamping B7 gently on the drive body LKS by hand do not force Screw the cylinder head screws M6 of the adjustable clamping B7 a...

Страница 18: ...e bracket K21K M6 Make sure they are parallel to casement edge Casement bracket center and rack must be in line Determine fastenings for casement bracket F10 6 frame bracket K21K and for frame bracket...

Страница 19: ...arefully clear away drilling swarfs to prevent seals from being damaged Avoid surface scratches for example by using masking tape Secure fasteners against loosening e g by applying removable thread lo...

Страница 20: ...propriate cross section for mounting dimensions see drill holes Installation stepe 3 or project specific documents and drawings Note Screws for mounting on the window are to be provided by the custome...

Страница 21: ...s s 300 mm max 2 5 A IP 54 0 C 70 C 110 x 110 x 66 mm Motion monitoring up to 3 drives 2 sequential controls DIP switches for settings Connection terminals 2 5 mm 24V Installation step 6 Electric conn...

Страница 22: ...he homepage of Firm aUM lleR aUMatIc GmbH www aumueller gmbh de Safety CheCk anD teSt Run Formula to calculate the required wire cross section of a supply line Calculation example Available data cut o...

Страница 23: ...ear or damages of cables and fastening elements must be performed During maintenance contaminations must be removed from the drive Fastenings and clamping screws must be checked for tightness Test run...

Страница 24: ...or delivered material is twelve months Warranty and liability claims for personal injuries or material damages are excluded if caused by one or more of the following No proper incoming goods inspectio...

Страница 25: ...25 LKS S2 24V DC Notes 08...

Страница 26: ...26 LKS S2 24V DC Notes 08...

Страница 27: ...s and Conditions of aUM lleR aUtoMatIc GmbH apply to all offers supplies and services The publication of these assembly and commissioning instructions supersedes all previous editions CeRtifiCate anD...

Страница 28: ...9000028501_V0 1_KW05 20...

Отзывы: