happen until the respective limit switch is hit (unless the switch is bypassed).
•
Close OFF time: This parameter decides the amount of time (in s) the actuator shuts
off before running in open direction for Open ON time (in s). This continues to
happen until the respective limit switch is hit (unless the switch is bypassed).
Programmable relays
As per standard, two relays are given for customer end information - Fault Relay &
Optional Relay 1. There are about 6-8 more additional relays that have been added
along with this module. Each of these relays can be configured for the following 27 faults /
statues as given below.
Real time clock (RTC)
This module has a Real time clock that is used to obtain the time-stamp for Event logging.
The RTC can be configured by AUMA Utility Software or by manually setting the RTC in
Program Mode settings. The RTC is powered by a Super Capacitor when the power is off
which is another added feature of this module. The Super Capacitor takes about 2 hours
to charge and can supply power up to 20 days to the RTC.
Power supply
The Power Supply Card used in this module has several new features. The features are
as follows:
•
Under Voltage Protection
•
Over Voltage Protection
·
List of available relays
o
Fault Relay
o
Assignable Relay (5relays)
o
Latching Relay ( 2 relays)
·
Available Programmable options are:
o
Opened (Open Limit Trip)
o
Closed (Close Limit Trip)
o
Remote Local stop
o
Local Stop
o
Open Torque Trip
o
Close Torque Trip
o
Loss of Phase
o
TH-Trip
o
TOLR Trip
o
Control Supply Fail
o
Phase reversal
o
Jammed Valve
o
Power ON
o
Program Mode Indication
o
SP Reached ( via DAC/MODBUS)
o
Selector SW LOCAL
o
Selector SW OFF
o
Selector SW REMOTE
o
ESD Pressed
o
24V DC Fail
o
Space Heater Fail
o
Running Open
o
Running Close
o
Remote Selector SW EN
o
PVST Fail
o
Intermediate Pos
o
4-20mA Signal Fail
Weather proof actuators with 3.XMP-SIL &
Data logging
Содержание SA3-SA100
Страница 18: ...18 Weather proof actuators with 3 XMP SIL Data logging...
Страница 19: ...19 Weather proof actuators with 3 XMP SIL Data logging...
Страница 20: ...20 Weather proof actuators with 3 XMP SIL Data logging...
Страница 21: ...21 Weather proof actuators with 3 XMP SIL Data logging...
Страница 22: ...22 Weather proof actuators with 3 XMP SIL Data logging...
Страница 23: ...23 Weather proof actuators with 3 XMP SIL Data logging...
Страница 25: ...25 Weather proof actuators with 3 XMP SIL Data logging...
Страница 28: ...28 Weather proof actuators with 3 XMP SIL Data logging...
Страница 31: ...31 Weather proof actuators with 3 XMP SIL Data logging...
Страница 41: ...41 Wiring Diagram for SIL with Pro bus DP Weather proof actuators with 3 XMP SIL Data logging...
Страница 42: ...42 Wiring Diagram for SIL without Pro bus DP Weather proof actuators with 3 XMP SIL Data logging...
Страница 43: ...43 Wiring Diagram for SIL without Pro bus DP Weather proof actuators with 3 XMP SIL Data logging...
Страница 44: ...44 SIL Certi cate Weather proof actuators with 3 XMP SIL Data logging...
Страница 46: ...46 Weather proof actuators with 3 XMP SIL Data logging...
Страница 47: ...47 Weather proof actuators with 3 XMP SIL Data logging...