2. Specification
Model
AL-H18/4DR1(U)
AL-H24/4DR1(U)
AL-H36/4DR1(U)
Power Supply
V~,Hz,
Ph
220~240,50,1
220~240,50,1
220~240,50,1
Max. Input Consumption
W
2400
3470
4360
Max. Current
A
12.1
17.5
19.8
Capacity
Cooling
Btu/h
20000-18000-5500
26500-24000-7200
40000-36000-1080
0
W
5610-5100-1530
7920-7200-2160
11000-10000-3000
Heating
Btu/h
20140-19000-4750
29700-27000-6750
43125-37500-1125
0
W
5936-5600-1400
8690-7900-1975
13225-11500-3450
DC Inverter
Compressor
Model
ATD141RDPA8JT
A
ATL232UDPC9AQ
DA250S2C-30MT
Type
ROTARY
ROTARY
ROTARY
Brand
Shanghai Hitachi
Shanghai Hitachi
GMCC
Capacity
W
5560
6520
7690
Input
W
1255
2070
2120
Frequency range
Hz
16.7-120
20-240
12-120
Rated Current(RLA)
A
4.2
8.8
8.85
Locked Rotor Amp(LRA)
A
30
32
45
Refrigerant Oil
ml
480 (68HES-H)
630 (HAF68D1C)
820 (ESTER OIL
VG74)
Outdoor Fan
Motor
Model
CW65A
CW70A
YDK120-6
Brand
weiling
AUKS/weiling
Weiling
Output Power x Fan
quantity
W
65×1
70×1
120×1
Capacitor
uF
4
4
5
Speed
r/min
830/710/550
830/700/500
830/720/620
Coil
a.Number Of Row
2
2
2
b.Tube Pitch(a)x Row
Pitch(b)
mm
22×19.05
22×19.05
22×19.05
c.Fin Pitch
mm
1.6
1.6
1.6
d.Fin Material
Hydrophilic
aluminum fin
Hydrophilic
aluminum fin
Hydrophilic
aluminum fin
e.Tube Outside Dia.And
Material
mm
φ7.94
,
Inner
grooved
φ7.94
,
Inner
grooved
φ7.94
,
Inner
grooved
f.Coil Length x Height x
Width
mm
736×550×38.1
740×660×38.1
836×761×38.1
g.Heat Exchanging Area
㎡
16.92
21.26
27.23
Air Flow Volume
CFM
1529
1647
2294
m
3
/h
2600
2800
3900
Noise Level
dB(A)
55
60
60
Dimension(W×
D×H)
Net
mm
800×300×590
800×300×690
900×320×790
Packing
mm
930×410×660
930×410×760
1030×430×850
Weight
Net
kg
45
56
62
Gross
kg
49
60
67
Refrigerant
Type/Quantity
Type
R410A
R410A
R410A
Charged Volume
kg
1.3
1.7
1.9
Design Pressure
MPa
4.4
4.4
4.4
Refrigerant
Piping
Liquid Side
mm
6.35(1/4)
9.52(3/8)
9.52(3/8)
Gas Side
mm
12.7(1/2)
15.88(5/8)
15.88(5/8)
Drainage
mm
R3/4in(DN20)
R3/4in(DN20)
R3/4in(DN20)
Max. Length
m
20
30
30
Содержание AL-H18/4DR1(U)
Страница 1: ...AUKS DC Inverter 1 Drive1 50HZ R410A 1 Service manual DC Inverter 1 Drive 1 50Hz R410a...
Страница 3: ...AUKS DC Inverter 1 Drive1 50HZ R410A General description 3 Part 1 General description 1 Nomenclature...
Страница 5: ...AUKS DC Inverter 1 Drive1 50HZ R410A General description 5...
Страница 7: ...AUKS DC Inverter 1 Drive1 50HZ R410A General description 7...
Страница 21: ...AUKS DC Inverter 1 Drive1 50HZ R410A Four way cassette 21 Introduction of control board socket...
Страница 46: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ceiling Floor Type 46 Introduction of control board socket...
Страница 55: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ceiling Floor Type 55...
Страница 68: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ducted type Indoor unit 68 Introduction of control board socket...
Страница 69: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ducted type Indoor unit 69 6 Fan Performance ALMD H18 4DR1 ALMD H24 4DR1...
Страница 70: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ducted type Indoor unit 70 ALMD H36 4DR1 ALMD H48 5DR1 ALMD H60 5DR1...
Страница 89: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 89 AL H48 5DR1 U AL H60 5DR1 U...
Страница 92: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 92 Filter board...
Страница 109: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 109...
Страница 120: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 120 Communication failure between indoor and outdoor unit...
Страница 121: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 121 Outdoor protection phase sequence...
Страница 122: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 122 Cooling high pressure protection...
Страница 123: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 123 Heating high pressure protection...
Страница 124: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 124 Cooling low pressure protection...
Страница 125: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 125 Heating low pressure protection...
Страница 126: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 126 Cooling exhaust temperature protection...
Страница 127: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 127 Heating exhaust temperature protection...
Страница 128: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 128 Refrigerant shortage or four way valve failure protection...
Страница 129: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 129 Sensor failure protection...
Страница 131: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 131 Poor effect...
Страница 132: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 132...
Страница 133: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 133 Abnormal sound or viberation...
Страница 134: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 134...
Страница 135: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 135 Abnormal odor...
Страница 136: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 136 Air switch action when air conditioner starting up...
Страница 137: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 137 Air conditioner water leakage...
Страница 147: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 147 Wired controller XK 05...
Страница 148: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 148...
Страница 149: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 149 Installation of wired controller...