AUKS DC Inverter 1 Drive1 50HZ R410A Ceiling & Floor Type
39
Indoor Coil
a.Number Of Row
3
3
b.Tube Pitch(a)x Row Pitch(b)
mm
20.5×12.7
22×19.05
c.Fin Spacing
mm
1.6
1.6
d.Fin Material
Hydrophilic aluminum
fin
Hydrophilic aluminum
fin
e.Tube Outside Dia.and
Material
mm
φ7
,
Inner grooved
φ7.94
,
Inner grooved
f.Coil Length x Height x Width
mm
1300×246×38.1
1300×242×57.15
g.Heat Exchanging Area
m
2
13.69
20.55
Indoor Unit
Indoor Air Flow (Hi/Mi/Lo)
m
3
/h
1800/1440/1260
1800/1440/1260
Noise Level(Hi/Mi/Lo)
dB(A)
51/48/42
51/48/42
Net Dimension (W*H*D)
mm
1631×660×205
1630×660×205
Packing Dimension (W*H*D)
mm
1710×720×290
1710×720×290
Net Weight
Kg
44
44
Gross Weight
Kg
50
50
Refrigerant Pipe
Liquid Side
mm
9.52(3/8)
9.52(3/8)
Gas Side
mm
19.05(3/4)
19.05(3/4)
Drainage
mm
R3/4in(DN20)
R3/4in(DN20)
Max. Refrigerant Pipe Length
m
50
50
Max. Difference In Level
m
30
30
Operation Temperature Range
℃
16~32
16~32
Ambient Temperature Range(Cooling/Heating)
℃
16~49/-15~24
16~49/-15~24
Connection Wiring
Power Wiring( Indoor)
mm
2
3×1mm
3
3×1mm
3
Power Wiring( Outdoor)
mm
2
5×1.5mm
3
5×1.5mm
3
Signal Wiring
mm
2
2×1mm
2
2×1mm
2
Wireless Remote Controller
YKR-L/300E
YKR-L/300E
Application Area
m
2
56-93
64-107
Qty’per 20’& 40’&40HQ(Only For Reference)
Set
24/50/53
24/50/53
Note:
1.
Working condition of the cooling capacity measured: Inside the room DB temperature 27
℃
,WB
temperature19
℃
;Outside of the room DB temperature 35
℃
,WB temperature 24
℃
;Working condition
of the heating capacity measured:Inside the room DB temperature 20
℃
,Outside of the room DB
temperature 7
℃
,WB temperature 6
℃。
2. Parameters above are all measured when the connecting pipe is 5 meters.
3. Parameters above may be modified as product improvement. We keep the right to change the product
specifications without prior notice, please take the parameters listed on the nameplate as criterion.
Содержание AL-H18/4DR1(U)
Страница 1: ...AUKS DC Inverter 1 Drive1 50HZ R410A 1 Service manual DC Inverter 1 Drive 1 50Hz R410a...
Страница 3: ...AUKS DC Inverter 1 Drive1 50HZ R410A General description 3 Part 1 General description 1 Nomenclature...
Страница 5: ...AUKS DC Inverter 1 Drive1 50HZ R410A General description 5...
Страница 7: ...AUKS DC Inverter 1 Drive1 50HZ R410A General description 7...
Страница 21: ...AUKS DC Inverter 1 Drive1 50HZ R410A Four way cassette 21 Introduction of control board socket...
Страница 46: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ceiling Floor Type 46 Introduction of control board socket...
Страница 55: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ceiling Floor Type 55...
Страница 68: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ducted type Indoor unit 68 Introduction of control board socket...
Страница 69: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ducted type Indoor unit 69 6 Fan Performance ALMD H18 4DR1 ALMD H24 4DR1...
Страница 70: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ducted type Indoor unit 70 ALMD H36 4DR1 ALMD H48 5DR1 ALMD H60 5DR1...
Страница 89: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 89 AL H48 5DR1 U AL H60 5DR1 U...
Страница 92: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 92 Filter board...
Страница 109: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 109...
Страница 120: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 120 Communication failure between indoor and outdoor unit...
Страница 121: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 121 Outdoor protection phase sequence...
Страница 122: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 122 Cooling high pressure protection...
Страница 123: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 123 Heating high pressure protection...
Страница 124: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 124 Cooling low pressure protection...
Страница 125: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 125 Heating low pressure protection...
Страница 126: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 126 Cooling exhaust temperature protection...
Страница 127: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 127 Heating exhaust temperature protection...
Страница 128: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 128 Refrigerant shortage or four way valve failure protection...
Страница 129: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 129 Sensor failure protection...
Страница 131: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 131 Poor effect...
Страница 132: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 132...
Страница 133: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 133 Abnormal sound or viberation...
Страница 134: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 134...
Страница 135: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 135 Abnormal odor...
Страница 136: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 136 Air switch action when air conditioner starting up...
Страница 137: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 137 Air conditioner water leakage...
Страница 147: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 147 Wired controller XK 05...
Страница 148: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 148...
Страница 149: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 149 Installation of wired controller...