AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit
106
Power supply:220V~,50Hz
Capacity
(BTU)
Model
Power supply
Indoor power
cable
Outdoor
power
Signal wire
18000
ALCA-H18/4DR1
ALCF-H18/4DR1
ALMD-H18/4DR1
Outdoor unit
380-415V
3N~50Hz
IndoorUnit
220-240V
~
50Hz
separate
3×1mm2
3×2.5mm2
2×1mm2
24000
ALCA-H24/4DR1
ALCF-H24/4DR1
ALMD-H24/4DR1
3×1mm2
3×2.5mm2
2×1mm2
36000
ALCA-H36/4DR1
ALCF-H36/4DR1
ALMD-H36/4DR1
3×1mm2
3×4mm2
2×1mm2
Power supply 380V~415V 3N,50Hz
Capacity
(BTU)
Model
Power supply
Indoor power
cable
Outdoor
power
Signal wire
48000
ALCA-H48/5DR1
ALCF-H48/5DR1
ALMD-H48/5DR1
Outdoor unit
380-415V
3N~50Hz
IndoorUnit
220-240V
~
50Hz
separate
3×1mm2
5×2.5mm2
2×1mm2
60000
ALCA-H60/5DR1
ALCF-H60/5DR1
ALMD-H60/5DR1
Notice:
◇
Above mentioned power supply cord is the cable which connect air on-off of indoor to indoor/outdoor
unit. Power supply cord of indoor/outdoor unit is the power supply cable connecting indoor and
outdoor unit
◇
The section area of power supply cord core is minimized one. To avoid voltage pressure dropped
down, while longer power supply cord needed, the section area should be enlarged for one gauge.
◇
The connection wires to indoor unit is the cable of 27IEC53(RVV) type, 300/500V; while the
connection wires to outdoor unit and the connection wires from outdoor to indoor unit is the multi-end
of cable (neoprene)of 245IEC57(YZW)type,300/500V. if the single core with double skin type of cable
is chosen for installation,, please choose 1# gauge of section area and wrapped with special jacket
for electrician.
◇
All of the ceiling/floor type unit is without accessorial electric heating
8.3.3 wire connection
Remove electric control box cover of indoor unit, connect the wires in accordance with the electri
diagram mentioned on the back of the cover. The wire ends must be tightly fixed into terminal boards
without ease. The earth wire must be fixed into appointed position.
Outdoor wire connection
◇
Remove the electric item cover, which is positioned in the right side of outdoor unit, connect the wires
in accordance with the electric diagram on the back of the cover.
◇
Be sure that pressing the wires tightly with the terminal boards while it through the board, the wire
ends must be tightly fixed into terminal boards. The earth wire must be fixed into appointed position.
◇
After all the wire connected, bundle connection pipe, connection wires and drainage pipe with strips
like mentioned drawing below:
Содержание AL-H18/4DR1(U)
Страница 1: ...AUKS DC Inverter 1 Drive1 50HZ R410A 1 Service manual DC Inverter 1 Drive 1 50Hz R410a...
Страница 3: ...AUKS DC Inverter 1 Drive1 50HZ R410A General description 3 Part 1 General description 1 Nomenclature...
Страница 5: ...AUKS DC Inverter 1 Drive1 50HZ R410A General description 5...
Страница 7: ...AUKS DC Inverter 1 Drive1 50HZ R410A General description 7...
Страница 21: ...AUKS DC Inverter 1 Drive1 50HZ R410A Four way cassette 21 Introduction of control board socket...
Страница 46: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ceiling Floor Type 46 Introduction of control board socket...
Страница 55: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ceiling Floor Type 55...
Страница 68: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ducted type Indoor unit 68 Introduction of control board socket...
Страница 69: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ducted type Indoor unit 69 6 Fan Performance ALMD H18 4DR1 ALMD H24 4DR1...
Страница 70: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ducted type Indoor unit 70 ALMD H36 4DR1 ALMD H48 5DR1 ALMD H60 5DR1...
Страница 89: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 89 AL H48 5DR1 U AL H60 5DR1 U...
Страница 92: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 92 Filter board...
Страница 109: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 109...
Страница 120: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 120 Communication failure between indoor and outdoor unit...
Страница 121: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 121 Outdoor protection phase sequence...
Страница 122: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 122 Cooling high pressure protection...
Страница 123: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 123 Heating high pressure protection...
Страница 124: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 124 Cooling low pressure protection...
Страница 125: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 125 Heating low pressure protection...
Страница 126: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 126 Cooling exhaust temperature protection...
Страница 127: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 127 Heating exhaust temperature protection...
Страница 128: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 128 Refrigerant shortage or four way valve failure protection...
Страница 129: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 129 Sensor failure protection...
Страница 131: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 131 Poor effect...
Страница 132: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 132...
Страница 133: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 133 Abnormal sound or viberation...
Страница 134: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 134...
Страница 135: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 135 Abnormal odor...
Страница 136: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 136 Air switch action when air conditioner starting up...
Страница 137: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 137 Air conditioner water leakage...
Страница 147: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 147 Wired controller XK 05...
Страница 148: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 148...
Страница 149: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 149 Installation of wired controller...