AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit
81
Max. Height
m
15
15
20
Operation Temperature Range
℃
16~32
16~32
16~32
Ambient
Temperature
Range(Cooling/Heating)
℃
16~49/-15~24
16~49/-15~24
16~49/-15~24
Connection
Wiring
Power Wiring
(
Indoor
)
mm
2
3×1mm
2
3×1mm
2
3×1mm
2
Power Wiring
(
Outdoor
)
mm
2
3×2.5mm
2
3×2.5mm
2
3×2.5mm
2
Signal Wiring
mm
2
2×1mm
2
2×1mm
2
2×1mm
2
Application Area
m
2
21-35
28-47
42-70
Stuffing
Quantity
20/40/40H
Unit
102/204/272
102/204/204
56/112/168
Note:
1.
Working condition of the cooling capacity measured: Inside the room DB temperature 27
℃
,WB
temperature19
℃
;Outside of the room DB temperature 35
℃
,WB temperature 24
℃
;Working
condition of the heating capacity measured:Inside the room DB temperature 20
℃
,Outside of the
room DB temperature 7
℃
,WB temperature 6
℃。
2. Parameters above are all measured when the connecting pipe is 5 meters.
3. Parameters above may be modified as product improvement. We keep the right to change the
product specifications without prior notice, please take the parameters listed on the nameplate as
criterion.
Model
AL-H48/5DR1(U)
AL-H60/5DR1(U)
Power Supply
V~,Hz,P
h
380~415,50,3
380~415,50,3
Max. Input Consumption
W
7300
7700
Max. Current
A
12.3
13.0
Capacity
Cooling
Btu/h
51800-48000-14400
63000-60000-18000
W
15120-14000-4200
16800-16000-4800
Heating
Btu/h
56100-51000-17850
69300-63000-22050
W
17050-15500-5425
19800-18000-6300
DC Inverter
Compressor
Model
ATQ420D2UMU
ATQ420D2UMU
Type
ROTARY
ROTARY
Brand
GMCC
GMCC
Capacity
W
13100
13100
Input
W
3420
3420
Frequency range
Hz
12-120
12-120
Rated Current(RLA)
A
6.9
6.9
Locked Rotor Amp(LRA)
A
44
44
Refrigerant Oil
ml
1400 (POE VG74)
1400 (POE VG74)
Outdoor Fan Motor
Model
WC55-6
WC55-6
Brand
weiling
weiling
Output Power x Fan quantity
W
55×2
55×2
Capacitor
uF
3×2
3×2
Speed
r/min
780/660/530
780/660/530
Coil
a.Number Of Row
2
2
b.Tube Pitch(a)x Row Pitch(b)
mm
22×19.05
22×19.05
Содержание AL-H18/4DR1(U)
Страница 1: ...AUKS DC Inverter 1 Drive1 50HZ R410A 1 Service manual DC Inverter 1 Drive 1 50Hz R410a...
Страница 3: ...AUKS DC Inverter 1 Drive1 50HZ R410A General description 3 Part 1 General description 1 Nomenclature...
Страница 5: ...AUKS DC Inverter 1 Drive1 50HZ R410A General description 5...
Страница 7: ...AUKS DC Inverter 1 Drive1 50HZ R410A General description 7...
Страница 21: ...AUKS DC Inverter 1 Drive1 50HZ R410A Four way cassette 21 Introduction of control board socket...
Страница 46: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ceiling Floor Type 46 Introduction of control board socket...
Страница 55: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ceiling Floor Type 55...
Страница 68: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ducted type Indoor unit 68 Introduction of control board socket...
Страница 69: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ducted type Indoor unit 69 6 Fan Performance ALMD H18 4DR1 ALMD H24 4DR1...
Страница 70: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ducted type Indoor unit 70 ALMD H36 4DR1 ALMD H48 5DR1 ALMD H60 5DR1...
Страница 89: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 89 AL H48 5DR1 U AL H60 5DR1 U...
Страница 92: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 92 Filter board...
Страница 109: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 109...
Страница 120: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 120 Communication failure between indoor and outdoor unit...
Страница 121: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 121 Outdoor protection phase sequence...
Страница 122: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 122 Cooling high pressure protection...
Страница 123: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 123 Heating high pressure protection...
Страница 124: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 124 Cooling low pressure protection...
Страница 125: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 125 Heating low pressure protection...
Страница 126: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 126 Cooling exhaust temperature protection...
Страница 127: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 127 Heating exhaust temperature protection...
Страница 128: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 128 Refrigerant shortage or four way valve failure protection...
Страница 129: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 129 Sensor failure protection...
Страница 131: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 131 Poor effect...
Страница 132: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 132...
Страница 133: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 133 Abnormal sound or viberation...
Страница 134: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 134...
Страница 135: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 135 Abnormal odor...
Страница 136: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 136 Air switch action when air conditioner starting up...
Страница 137: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 137 Air conditioner water leakage...
Страница 147: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 147 Wired controller XK 05...
Страница 148: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 148...
Страница 149: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 149 Installation of wired controller...